Desa UNVENTED (VENT-FREE) PROPANE/LPGAS LOG HEATER Trouble, Shooting, Cleaning, Maintenance

Models: UNVENTED (VENT-FREE) PROPANE/LPGAS LOG HEATER

1 36
Download 36 pages 27.05 Kb
Page 25
Image 25
CLEANING

CLEANING

 

WARNING

AND

WARNING ICONG 001

Turn off heater and let cool before cleaning.

MAINTENANCE

 

 

 

 

 

 

WARNING ICONG 001

CAUTION

You must keep control areas, burner, and circulating air passage- ways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a qualified service person. Heater may need more frequent cleaning due to excessive lint from carpeting, bedding material, etc.

ODS/PILOT AND BURNER

• Use a vacuum cleaner or small, soft bristled brush to clean.

LOGS

If you remove logs for cleaning, refer to Installing Logs, page 20 and 21, to properly replace logs.

Replace log(s) if broken or chipped (dime-sized or larger).

TROUBLE-

 

 

 

WARNING ICONG 001WARNING

 

 

SHOOTING

 

 

 

 

 

 

Turn off and unplug heater and let cool before servicing. Only a

Note: All troubleshooting

 

qualified service person should service and repair heater.

 

 

 

 

 

 

 

 

 

 

 

 

items are listed in order of

 

 

 

 

 

 

 

 

 

WARNING ICONG 001CAUTION

 

 

operation.

 

 

 

 

 

 

 

Never use a wire, needle, or similar object to clean ODS/pilot. This

 

 

can damage ODS/pilot unit.

 

 

 

 

 

 

 

 

 

OBSERVED

POSSIBLE

 

 

 

PROBLEM

CAUSE

REMEDY

 

 

 

 

 

 

 

When ignitor button

1.

Ignitor electrode not

1.

Reconnect ignitor cable

 

is pressed, there is no

 

connected to ignitor cable

 

 

 

spark at ODS/pilot

2.

Ignitor cable pinched or

2.

Free ignitor cable if

 

 

 

 

wet

 

pinched by any metal or

 

 

 

 

 

 

tubing. Keep ignitor

 

 

 

 

 

 

cable dry

 

 

 

3.

Piezo ignitor nut is loose

3.

Tighten nut holding

 

 

 

 

 

 

piezo ignitor to base

 

 

 

 

 

 

panel of log set. Nut is

 

 

 

 

 

 

located behind base

 

 

 

 

 

 

panel.

 

 

 

4.

Broken ignitor cable

4.

Replace ignitor cable

 

 

 

5.

Bad piezo ignitor

5.

Replace piezo ignitor

 

 

 

6.

Ignitor electrode posi-

6.

Replace ignitor

 

 

 

 

tioned wrong

 

 

 

 

 

7.

Ignitor electrode broken

7.

Replace ignitor

25

103310

Page 25
Image 25
Desa UNVENTED (VENT-FREE) PROPANE/LPGAS LOG HEATER installation manual Trouble, Shooting, Cleaning, Maintenance