INSTALLING
Continued
10
INSTALLATION AND CLEARANCES (Vent-Free Operation Only)
WARNING
Maintain the minimum clearances. If you can, provide greater clear- ances from floor, ceiling, and adjoining wall.
MINIMUM FIREPLACE CLEARANCE
TO COMBUSTIBLE MATERIALS
Log Size |
|
|
| Side Wall |
| Ceiling | ||
|
|
|
|
|
|
| ||
18” and 24" |
|
| 16" |
|
| 42" | ||
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| LOG SIZING REQUIREMENTS |
| |||||
|
|
|
|
|
|
|
|
|
Log |
|
|
| Minimum Firebox Size |
| |||
Size |
| Height |
| Depth |
| Front Width | ||
|
|
|
|
|
|
|
|
|
18" |
| 17" |
|
| 14" |
|
| 20" |
24" |
| 17" |
|
| 14" |
|
| 26" |
|
|
|
|
|
|
|
|
|
Carefully follow the instructions below. This will ensure safe installation into a masonry, U.L. listed manufactured fireplace, or AGA design certified
Minimum Wall and Ceiling Clearances (see Figure 4)
A.Clearances from the side of the fireplace opening to any combustible wall should not be less than 16 inches.
B.Clearances from the top of the fireplace opening to the ceiling should not be less than 42 inches.
42"
16"
Left and Right
Sides
Figure 4 - Minimum Clearance to Wall and Ceiling
103310