INSTALLING |
| WARNING ICONG 001CAUTION |
Continued |
| |
Avoid damage to regulator. Hold gas regulator with wrench when | ||
| connecting it to gas piping and/or fittings. | |
|
| A.G.A. |
|
| Manual Shutoff Valve |
| From | With 1/8" NPT Tap* |
| External Regulator | Approved Flexible |
| Gas Hose (if allowed | |
| (11" W.C.** to | |
| by local codes) | |
| 14" W.C. | |
|
| |
| Pressure) | Gas |
|
| |
|
| Regulator |
Tee Joint |
| |
Pipe | 3" Minimum | |
Nipple | ||
Cap |
| |
Sediment | Figure 14 - Gas Connection | |
Trap | ||
|
*Purchase the optional A.G.A.
**Minimum inlet pressure for purpose of input adjustment.
CHECKING GAS CONNECTIONS
WARNING
WARNING ICONG 001
Test all gas piping and connections for leaks after installing or servicing. Correct all leaks at once.
WARNING
WARNING ICONG 001
Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.
CAUTION
WARNING ICONG 001
Make sure external regulator has been installed between propane supply and heater. See guidelines under Connecting to Gas Sup- ply, page 15.
Pressure Testing gas Supply Piping system
Test Pressures In Excess Of 1/2 PSIG
1. Disconnect heater and its individual manual shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage heater regulator.
2. Cap off open end of gas pipe where manual shutoff valve was connected.
Continued | 17 |
|
101309