OPERATING | 5. | Turn control knob counterclockwise | to the PILOT position. Press in | ||
| |||||
| control knob for five (5) seconds (see Page 20). | ||||
HEATER |
| Note: You may be running this heater for the first time after hooking up to gas | |||
Thermostat- |
| supply. If so, the control knob may need to be pressed in for 30 seconds or less. | |||
| This will allow air to bleed from the gas system. | ||||
Controlled Models |
| • If control knob does not pop out when released, contact a qualified service | |||
Continued |
| person or gas supplier for repairs. |
| ||
6. With control knob pressed in, press and release ignitor button. This will light pilot. | |||||
| |||||
|
| The pilot is attached to the front burner. If needed, keep pressing ignitor button | |||
|
| until pilot lights. |
|
|
Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, below.
7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.
Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety inter- lock system. Wait one (1) minute for system to reset before lighting pilot again.
Thermocouple | Ignitor Electrode |
| Pilot Burner |
Figure 22 - Pilot
8. Turn control knob counterclockwise
CAUTION
WARNING ICON | G 001 |
Do not try to adjust heating levels by using the manual shutoff valve.
TO TURN OFF GAS TO APPLIANCE
Shutting Off Heater
1. Turn control knob clockwise Clockwise to the OFF position.
Shutting Off Burners Only (pilot stays lit)
1. Turn control knob clockwise Clockwise to the PILOT position.
THERMOSTAT CONTROL OPERATION
The thermostat control knob can be set to any comfort level between Hi and Lo. The thermostat will gradually modulate the heat output and flame height from higher to lower settings, or pilot, in order to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.
Note: Selecting the Hi setting with the control knob will cause the burner to remain fully on, without modulating down in most cases.
MANUAL LIGHTING PROCEDURE
1.Follow steps 1 through 5 under Lighting Instructions, page 20.
2.Depress control knob and light pilot with match.
3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30
seconds, release control knob. Now follow step 8, above. | 21 |
101309