Desa UNVENTED (VENT-FREE) PROPANE GAS LOG HEATER Models, Manually-Controlled, Operating, Heater

Models: UNVENTED (VENT-FREE) PROPANE GAS LOG HEATER

1 40
Download 40 pages 39.4 Kb
Page 23
Image 23
Manually-Controlled
C-clockwise
C-clockwise

OPERATING

5.

Press in control knob and turn counterclockwise C-clockwiseto the PILOT position.

 

Keep control knob pressed in for five (5) seconds (see Figure 23).

HEATER

 

 

Note: You may be running this heater for the first time after hooking up to gas

Manually-Controlled

 

supply. If so, the control knob may need to be pressed in for 30 seconds. This will

 

allow air to bleed from the gas system.

 

Models

 

 

 

• If control knob does not pop out when released, contact a qualified service

Continued

 

 

person or gas supplier for repairs.

 

 

6. With control knob pressed in, press and release ignitor button. This will light pilot.

 

 

The pilot is attached to the front burner. If needed, keep pressing ignitor button

 

 

until pilot lights.

 

 

 

Note: If pilot does not light, contact a qualified service person or gas supplier for

 

 

repairs. Until repairs are made, light pilot with match. To light pilot with match,

 

 

see Manual Lighting Procedure, below.

 

 

7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds,

 

 

release control knob.

 

 

 

Note: If pilot goes out, repeat steps 3 through 7.

Ignitor Electrode

 

 

 

 

 

Thermocouple

Pilot Burner

 

 

 

Figure 24 - Pilot

8. Turn control knob counterclockwise Models to the LOW position. The front burner should light. Set control knob to either HIGH, MEDIUM, or LOW. To turn control knob from LOW to a higher setting, press in the control knob and turn

counterclockwise see Manual Lighting Procedure, below. . On LOW and MEDIUM positions, only front burner operates. On HIGH position, front and rear burner operates.

WARNING

WARNING ICON

G 001

HIGH, MEDIUM, and LOW are locked positions. You must press in control knob before turning it from these positions. Do not operate heater between locked positions or sooting could occur.

CAUTION

WARNING ICON

G 001

Do not try to adjust heating levels by using the manual shutoff valve.

TO TURN OFF GAS TO APPLIANCE

Shutting Off Heater

 

 

1.

Press in and turn control knob clockwise

Clockwise

to the PILOT position.

2.

Press in control knob and turn clockwise

Clockwise

to the OFF position.

Shutting Off Burners Only (pilot stays lit)

1. Press in and turn control knob clockwise ClockwiseManual background to the PILOT position.

MANUAL LIGHTING PROCEDURE

1.Follow steps 1 through 5 under Lighting Instructions, page 22.

2.Depress control knob and light pilot with match.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30

seconds, release control knob. Now follow step 8, above.

23

101309

Page 23
Image 23
Desa UNVENTED (VENT-FREE) PROPANE GAS LOG HEATER Models, Manually-Controlled, Operating, Heater, Manual Lighting Procedure