OUTSIDE AIR KIT INSTALLATION GAS LINE INSTALLATION

7

OUTSIDE AIR KIT

INSTALLATION

The installation of the outside air kit must be installed during the rough framing of the fireplace due to the nature of its location. Outside combustion air can be accessed through an exterior wall or a vented crawl space (see Figure 13).

CAUTION: Air inlet ducts must not terminate in attic space.

The maximum height for the air inlet above the platform of fireplace is a minimum of 3 feet below the chimney cap.

For further details on the installation of the outside air kit, please refer to the instructions included with the air kit.

Secure Two Collars With

Duct Tape or ScrewsAir Inlet Termination

Air Inlet

Location

Must Allow

For Bushes

Or Snow

FOR UNVENTED ROOM HEATERS, ANSI\IAS\AGA Z21.11.2,

ARE TO BE INSTALLED IN THIS FIREPLACE.

1.To install, remove the knockout indentation on the refractor (or firebrick) wall located approximately 2 inches above the refractory hearth floor. The knockout indentation must be firmly tapped with any solid object until it is released. Remove frag- mented portion of refractory (see Figure 14).

2.Remove gas line cover plate on rear of fireplace and pull out insu- lation from gas line conduit sleeve, save insulation for reuse.

3.Run gas line into the fireplace through the rear at 111/4" from the floor and through gas line conduit sleeve (if using a raised platform, add height). Provide sufficient gas line into fireplace chamber for fitting connection (see Figure 15).

Note: Secure incoming gas line to wood framing to provide rigidity for threaded end.

4.Repack insulation around gas line and into sleeves openings. Seal any gaps between gas line and refractory knockout hole with refractory cement or commercial furnace cement. Install the decorative gas appliance or cap off gas line if desired.

Figure 13 - Air Kit Installation

GAS LINE INSTALLATION

WARNING: A qualified service person must con- nect fireplace to gas supply. Follow all local codes.

Outside of Fireplace

Remove

Insulation

Temporarily

(Do Not

Discard)

Gas Line

Conduit

Remove

Knockout

Replace Screws After

Removing Gas Line

Cover Plate

Side Firebrick Finished Side

Refractory Knockout Plug, Remove by Tapping Lightly With A 1/2" Dowel

NOTICE: BEFORE YOU PROCEED, MAKE SURE YOUR GAS SUPPLY IS OFF!

A gas line may be installed for the purpose of installing a vented or vent-free decorative gas appliance available through your local distributor. Use only gas piping approved by local codes. When installing a gas line, a shutoff valve designed for installation outside the appliance is recommended.

The gas pipe is intended for connection to a decorative gas appliances that operate from natural or propane/LP fuel only: (1), incorporating an automatic shutoff device and, (2), complying with the Standard for Decorative Gas Appliances for Installation in Vented Fireplace, ANSI Z21.60-1990. ONLY UNVENTED GAS LOG SETS WHICH HAVE BEEN FOUND TO COMPLY WITH THE STANDARD

Figure 14 - Removing Knockout for Gas Line Installation

Side Firebrick

Outside ofFinished Side

Fireplace

Gas Line

Incoming

Provide Enough

1/2" Black

Conduit

Threaded End For

Iron Pipe

 

Fitting Connection

 

 

Repack

InsulationSeal Opening

With Refractory

Cement

Figure 15 - Running Gas Line

For more information, visit www.desatech.com

55253C

Page 7
Image 7
Desa V3610ST manual Outside AIR KIT Installation, GAS Line Installation

V3610ST specifications

The Desa V3610ST is an innovative solution designed to meet the heating needs of residential and commercial spaces. Renowned for its reliability and efficiency, this model stands out in the market with several noteworthy features and technologies.

At the heart of the Desa V3610ST lies its advanced heating technology. It utilizes a powerful yet energy-efficient propane gas system, delivering a maximum output of 30,000 BTUs. This ensures effective heating for medium-sized rooms, providing comfort during the cold months. The integrated thermostat allows for precise temperature control, enabling users to set their desired ambiance easily and efficiently.

One of the standout characteristics of the V3610ST is its sleek and modern design. The unit is finished in a stylish black or white, which allows it to blend seamlessly with various interior décors. Its compact size ensures that it doesn't take up excessive space, making it ideal for smaller rooms or apartments.

Another significant aspect of the Desa V3610ST is its user-friendly interface. The control panel is intuitive, allowing users to adjust settings effortlessly. The easy-to-read display gives real-time feedback on temperature settings, operating modes, and system diagnostics, ensuring optimal performance and ease of use.

The V3610ST also places a strong emphasis on safety. It comes equipped with advanced safety features such as an automatic shut-off system, ensuring peace of mind when the unit is in use. Additionally, the built-in oxygen depletion sensor monitors air quality and will shut down the heater if levels become unsafe, allowing for uninterrupted safety during operation.

In terms of installation, the Desa V3610ST does not require extensive modifications. It is designed for both vented and unvented applications, providing flexibility based on a user’s individual needs. This adaptability makes the unit suitable for various settings, from traditional homes to modern apartments.

Furthermore, the efficiency rating of the V3610ST is a key selling point. It boasts a high energy efficiency score, helping users save on heating bills while minimizing their carbon footprint. The combination of practicality, safety, and efficiency makes the Desa V3610ST a compelling choice for consumers looking to enhance their heating solutions.

In conclusion, the Desa V3610ST offers an impressive array of features, advanced technologies, and robust safety measures. Whether you are looking to heat a small living space or a larger area, this versatile unit promises reliability, style, and efficiency, making it a top contender in the heating appliance market.