18

FIREPLACE INSTALLATION

Installing Optional Blower Accessory (Cont.) Installing Gas Piping To Fireplace Location

FIREPLACE INSTALLATION

Continued

Blower Wiring Diagram

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

Variable

Fan SwitchFan Switch

(N.O.)

Off 1

2

Black

 

On

 

Blue

110/115

V.A.C.

Black

Blower

 

White

Motor

Green

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 29 - Blower Wiring Diagram for Thermostat-Controlled Models

INSTALLING GAS PIPING TO FIREPLACE LOCATION

WARNING: A qualified service person must con- nect fireplace to gas supply. Follow all local codes.

CAUTION: For propane/LP units, never connect fireplace directly to the propane/LP supply. This heater requires an external regulator (not supplied). Install the external regulator between the fireplace and propane/LP supply.

Installation Items Needed

Before installing fireplace, make sure you have the items listed below.

external regulator (supplied by installer)

piping (check local codes)

sealant (resistant to propane/LP gas)

equipment shutoff valve *

test gauge connection *

sediment trap

tee joint

pipe wrench

approved flexible gas line with gas connector (if allowed by lo- cal codes)

*A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the CSA design-certified equipment shutoff valve from your retailer.

For propane/LP connection only, the installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure, fireplace regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 31, page 19. Pointing the vent down protects it from freezing rain or sleet.

CAUTION: Use only new, black iron or steel pipe. Internally-tinned copper tubing may be used in cer- tain areas. Check your local codes. Use pipe of 1/2" inside diameter or greater to allow proper gas volume to fireplace. If pipe is too small, undue loss of volume will occur.

Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from fireplace (see Figure 31, page 19).

IMPORTANT: Install main gas valve (equipment shutoff valve) in an accessible location. The main gas valve is for turning on or shutting off the gas to the appliance.

Check your building codes for any special requirements for locating equipment shutoff valve to fireplaces.

Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged fireplace valves.

WARNING: Use pipe joint sealant that is resistant to liquid petroleum (LP) gas.

External

Propane/LP

Regulator

Supply Tank

Vent

Pointing

Down

Figure 30 - External Regulator with Vent Pointing Down (Propane/LP Only)

For..com

111253-01C

Page 18
Image 18
Desa V36EP-A SERIES, V36EN-A SERIES, VV36EPB(1) SERIES, VV36ENB(1) SERIES Installing GAS Piping to Fireplace Location

V36EP-A SERIES, V36EN-A SERIES, VV36EPB(1) SERIES, VV36ENB(1) SERIES specifications

The Desa V36EP-A SERIES, V36EN-A SERIES, VV36EPB(1) SERIES, and VV36ENB(1) SERIES represent an innovative lineup of gas vent-free fireplaces designed to enhance the ambiance of any living space while providing efficient heating. These models are particularly noted for their cutting-edge technology and elegant designs, ensuring they blend seamlessly with various interior styles.

The V36EP-A and V36EN-A SERIES are equipped with a highly efficient burner system that provides an impressive heat output without the need for a chimney or venting, making them highly suitable for both new constructions and renovations. These models utilize advanced control systems that allow for easy adjustment of flame height and heat levels, thereby providing users with precise control over their environment.

The VV36EPB(1) SERIES and VV36ENB(1) SERIES take these features a step further with their improved efficiency ratings and attractive detailing. These models feature realistic flame patterns and log sets that mimic the look of traditional wood-burning fireplaces, creating a warm and inviting atmosphere. The ceramic fiber logs not only enhance visual appeal but also contribute to better heat distribution and retention.

One of the standout characteristics of these fireplace series is their incorporation of advanced safety features. Equipped with oxygen depletion sensors and a durable tempered glass front, they ensure safe operation without compromising on performance. The low emissions and reduced environmental impact align with modern energy efficiency standards.

Additionally, the Desa fireplaces come with options for remote controls and programmable thermostats, allowing for hassle-free operation and energy management. Customization options are also abundant, with various finishes and styles available to fit individual preferences and home decor.

In summary, the Desa V36EP-A SERIES, V36EN-A SERIES, VV36EPB(1) SERIES, and VV36ENB(1) SERIES deliver a combination of aesthetic appeal, modern technology, and practical heating solutions. Their vent-free designs make them versatile options for homeowners seeking efficient and stylish heating methods without the need for extensive installation. With their blend of safety, efficiency, and elegance, these fireplace series are poised to redefine comfort and style in home heating.