Desa (V)B36I, (V)B36L Venting Installation, Optional Outside air Kit Model AK4/AK4F, Chimney Pipe

Models: CWB36C (V)B36LI (V)B36I (V)B36L (V)B36

1 44
Download 44 pages 40.57 Kb
Page 7
Image 7
Venting Installation

Venting Installation

Optional Outside air Kit (Model AK4/AK4F)

Installation of outside air kit should be per- formed during rough framing of fireplace due to the nature of it's location. Outside combus- tion air is accessed through a vented crawl space (AK4F) or through a sidewall (AK4). See Figure 24 on page 15 for instruction of operating air kit.

Optional Outside air Kit (Model AK4/AK4F) CAUTION: Combustion air inlet ducts shall not terminate in attic space.

The maximum height for the air vent can not exceed 3 feet below the flue gas outlet of the termination.

Secure to Collars with Metal Tape, Screws or Straps (Min. of 1/4" x 20" in size)

 

Air Inlet

 

Location

 

Must Allow

 

For Bushes

 

or Snow

 

 

Air Inlet

Vented Crawl Space

 

Eyebrow

 

Vent Hood

(Check Local Codes

 

 

Required for

Before Installing in a

 

 

Wall Installation

Vented Crawl Space)

 

Figure 7 - Outside Air Kit

Chimney Pipe

DESA Heating, LLC chimney system con- sists of 12", 18", 24", 36" and 48" snap-lock, double-wall pipe segments, planned for maximum adaptability to individual site re- quirements. Actual lengths gained after fitting overlaps must be taken into consideration (lineal gain) and are given in lineal gain chart (see Figure 8).

Lineal gain is actual measurable length of a part after two or more parts are connected.

Chimney Pipe WARNING: The opening in collar around chimney at top of fireplacemustnotbeobstructed. Never use blown insulation to fill chimney enclosure.

12 3/8" Galvanized Manual background Outer Pipe

 

 

 

 

 

 

Hemmed

8" Stainless

 

 

 

 

 

End

 

 

 

 

 

 

Inner Pipe

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LINEAL GAIN

 

PART NO.

DESCRIPTION

GAIN

36"

 

Fireplace

37 1/2"

12-8DM

 

Pipe Section

10 5/8"

12-8HT

 

 

 

 

 

 

 

18-8DM

 

Pipe Section

16 5/8"

18-8HT

 

 

 

 

 

 

 

24-8DM

 

Pipe Section

23 5/8"

24-8HT

 

 

 

 

 

 

 

36-8DM

 

Pipe Section

34 5/8"

36-8HT

 

 

 

 

 

 

 

48-8DM

 

Pipe Section

46 5/8"

48-8HT

 

 

 

 

 

 

 

RT-8DM

Round Termination

6 7/8"*

RT-8HT

 

 

 

 

 

 

RTL-8DM

Round Termination

7 3/4"*

RTL-8HT

 

 

 

 

 

 

RTT-8DM

Round Termination

6 7/8" to

RTT-8HT

with Slip Section

23 1/8"*

RTTL-8DM

Round Termination

8 1/2" to

RTTL-8HT

with Slip Section

21 1/2"*

ET-8DM

Square Chase-Top

12"*

ET-8HT

 

 

 

 

 

 

ETO-8DM

Square Chase-Top

12"*

 

 

with Mesh

 

ETL-8DM

Square Chase-Top

7" to 15"*

ETL-8HT

with Slip Section

 

 

Square Chase-Top

12" to

ETLO-8DM

with Mesh & Slip

25 1/2"*

 

 

 

Section

 

 

 

 

*The lineal gain for the terminations is mea- sured to the flue gas outlet height.

Figure 8 - Lineal Gain

109034-01Gwww.desatech.com

Page 7
Image 7
Desa (V)B36I, (V)B36LI, CWB36C Venting Installation, Optional Outside air Kit Model AK4/AK4F, Chimney Pipe