Desa (V)B36I, (V)B36LI, CWB36C Continued, foot rule, Finishing fireplace, 10 Foot Rule

Models: CWB36C (V)B36LI (V)B36I (V)B36L (V)B36

1 44
Download 44 pages 40.57 Kb
Page 12
Image 12
10 foot rule

Venting Installation

Continued

10 foot rule

All flue gas outlet chimney terminations must extend a minimum of 3 feet in height above highest point where it passes through roof and must be at least 2 feet above highest point of the roof that is within a horizontal distance of 10 feet (see Figure 19).

10'

Level of

 

Flue Gas

 

 

 

 

Outlet

 

 

10'

 

2' Min.

3' Min.

 

 

 

 

2' Min.

3' Min.

 

 

Finishing fireplace

Combustible materials, such as wallboard, gypsum board, sheet rock, drywall, plywood, etc., may make direct contact with sides and top around fireplace face. It is important that combustible materials do not overlap face itself. Brick, glass, tile or other noncombustible materials may overlap front face provided they do not obstruct essential openings such as louvered slots. When overlapping with a noncombustible facing material, use only noncombustible mortar or adhesive.

Figure 19 - 10 Foot Rule

EFFECTIVE HEIGHT

EFFECTIVE HEIGHT

OF TERMINATION CAP

OF TERMINATION CAP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MIN. HEIGHT OF 22 FT. (WITH

2 ELBOW SETS) MAX. HEIGHT OF 50 FT.

 

 

MAX. HEIGHT

 

 

 

50 FT.

 

EFFECTIVE HEIGHT

EFFECTIVE HEIGHT

(ANY SYSTEM)

 

 

 

OF TERMINATION CAP OF TERMINATION CAP

 

 

14.5 FT.

14.5 FT.

 

 

MINIMUM

MINIMUM

UP TO

 

HEIGHT

HEIGHT

 

6FT. MAX.

 

 

 

 

 

UP TO

 

 

 

6FT. MAX.

30E-8DM

30E-8DM

 

 

Figure 20 - Typical Residential Installations

12

www.desatech.com

109034-01G

Page 12
Image 12
Desa (V)B36I, (V)B36LI, CWB36C Continued, foot rule, Finishing fireplace, 10 Foot Rule, Typical Residential Installations