14.Do not operate heater if any log is bro- ken. Do not operate heater if a log is chipped
15.Turn heater off and let cool before ser- vicing. Only a qualified service person should service and repair heater.
16.Operating heater above elevations of 4,500 feet may cause pilot outage.
17.To prevent performance problems, do not use propane/LP fuel tank of less than 100 lb. capacity.
LOCAL CODES
Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code, ANS Z223.1, also known as NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
UNPACKING
CAUTION: Do not remove the metal data plates attached to the heater base assembly. The data plates contain important warranty information.
1.Remove logs and heater base assem- bly from carton. Note: Do not pick up heater base assembly by burners. This could damage heater. Always handle base assembly by grate.
2.Remove all protective packaging ap- plied to logs and heater for shipment.
3.Check all items for any shipping dam- age. If damaged, promptly inform dealer where you bought heater.
PRODUCT
IDENTIFICATION
Crossover Log
Top Middle Log
Rear Log
Front Logs
Rear
Burner
Piezo Ignitor |
|
Front Burner | Bottom |
| Middle |
| Log |
Control Knob | Base Assembly |
| |
Figure 1 - Ember Master |
|
PRODUCT
FEATURES
OPERATION
This heater is clean burning. It requires no outside venting. There is no heat loss out a vent or up a chimney. Heat is generated by both realistic flames and glowing coals. This heater is designed for
SAFETY DEVICE
This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for
PIEZO IGNITION SYSTEM
This heater has a piezo ignitor. This system requires no matches, batteries, or other sources to light heater.