OWNER’S MANUAL

SAFETY

INFORMATION

Continued

14.Do not operate heater if any log is bro- ken. Do not operate heater if a log is chipped (dime-sized or larger).

15.Turn heater off and let cool before ser- vicing. Only a qualified service person should service and repair heater.

16.Operating heater above elevations of 4,500 feet may cause pilot outage.

17.To prevent performance problems, do not use propane/LP fuel tank of less than 100 lb. capacity.

LOCAL CODES

Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code, ANS Z223.1, also known as NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

UNPACKING

CAUTION: Do not remove the metal data plates attached to the heater base assembly. The data plates contain important warranty information.

1.Remove logs and heater base assem- bly from carton. Note: Do not pick up heater base assembly by burners. This could damage heater. Always handle base assembly by grate.

2.Remove all protective packaging ap- plied to logs and heater for shipment.

3.Check all items for any shipping dam- age. If damaged, promptly inform dealer where you bought heater.

PRODUCT

IDENTIFICATION

Crossover Log

Top Middle Log

Rear Log

Front Logs

Rear

Burner

Piezo Ignitor

 

Front Burner

Bottom

 

Middle

 

Log

Control Knob

Base Assembly

 

Figure 1 - Ember Master

 

PRODUCT

FEATURES

OPERATION

This heater is clean burning. It requires no outside venting. There is no heat loss out a vent or up a chimney. Heat is generated by both realistic flames and glowing coals. This heater is designed for vent-free opera- tion with flue damper closed. It has been tested and approved to ANS Z21.11.2 stan- dard for unvented heaters. State and local codes in some areas prohibit the use of vent- free heaters. This heater may also be oper- ated as a vented decorative (ANS Z21.60) product by opening the flue damper.

SAFETY DEVICE

This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.

PIEZO IGNITION SYSTEM

This heater has a piezo ignitor. This system requires no matches, batteries, or other sources to light heater.

105071

3

Page 3
Image 3
Desa VFP18MV, VFP24MV, VFP30MV installation manual Local Codes, Unpacking, Product Identification, Product Features