INSTALLATION
Continued
INSTALLING DAMPER CLAMP ACCESSORY FOR VENTED OPERATION
Note: When used as a vented decorative, appliance must be installed only in a
If your heater is a
1.The fireplace does not meet the clearance to combustibles requirements for
2.State or local codes do not permit
3.You prefer vented operation.
If reasons number 1 or 2 above apply to you, you must permanently open chimney flue damper. You must install the damper clamp accessory (to order, see Accessories, page 26). This will insure vented operation (see Figure 10). The damper clamp will keep damper open. Installation instructions are included with clamp accessory.
Damper | Damper | |
Clamp | ||
|
Damper
Damper
Clamp
Damper
Masonry Manufactured
FireplaceFireplace
Figure 10 - Attaching Damper Clamp
See chart below for minimum permanent flue | |
opening you must provide. Attach damper clamp | |
so the minimum permanent flue opening will be | |
maintained at all times. |
|
Area of Various Standard | |
Round Flues | |
Diameter (ins.) | Area (sq. ins.) |
5" | 20 sq. inches |
6" | 29 sq. inches |
7" | 39 sq. inches |
8" | 51 sq. inches |
Chimney | Minimum Permanent |
Height (ft.) | Flue Opening (sq. ins.) |
6' to 15' | 39 sq. inches |
15' to 30' | 29 sq. inches |
INSTALLING HEATER ASSEMBLY | |
WARNING: If installing in a | |
sunken fireplace, special care | |
is needed. You must raise the | |
fireplace floor to allow access | |
to heater control panel. This | |
will insure adequate air flow and | |
guard against sooting. Raise | |
fireplace floor with noncombus- | |
tible material. Make sure material | |
is secure. |
|
CAUTION: Do not pick up | |
heater assembly by logs. This | |
could damage unit. Only handle | |
assembly by grates. | |
IMPORTANT: Make sure the heater burners are | |
level. If heater is not level, heater will not work | |
properly. |
|
Installation Items Needed |
•control cover kit (provided with heater)
•approved flexible gas hose and fittings (pro- vided with heater) (if allowed by local codes)
•sealant (resistant to propane/LP gas, not provided)
12 | www.desatech.com |