INSTALLATION

Continued

Log #5

Log #6

Log #3

Log #2

Figure 27 - Installing Logs #5 and #6

OPERATING HEATER

FOR YOUR SAFETY

READ BEFORE LIGHTING

WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result causing property damage, per- sonal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighborʼs phone. Follow the gas supplierʼs instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, donʼt try to repair it, call a qualified service tech- nician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under

water.

LIGHTING

INSTRUCTIONS

WARNING:

If fireplace has glass doors, never operate this heater with glass doors closed. If you op- erate heater with doors closed, heat buildup inside fireplace will cause glass to burst. Make sure there are no obstructions across opening of fireplace.

You must operate this heater withafireplacescreeninplace. Make sure fireplace screen is closed before running heater.

NOTICE: During initial operation of new heater, burning logs will give off a paper-burning smell. Orange flame will also be pres- ent. Open damper or window to vent smell. This will only last a few hours.

Note: Home owners generally prefer to op- erate their heater with the chimney damper closed. This will put all the heat into the room. However, there may be times you will desire the full flames of the HI heat setting but will find the heat output excessive. You can open the chimney damper (if you have one) fully or partially to release some of the heat.

WARNING: Damper handle will be hot if heater has been running.

1.STOP! Read the safety information, col- umn 1.

2.Make sure equipment shutoff valve is fully open.

3.Press in and turn control knob clockwise to the OFF position (see Figure 28, page 20).

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information, column 1. If you donʼt smell gas, go to the next step.

112882-01D

www.desatech.com

19

Page 19
Image 19
Desa VGL18NRA Operating Heater, For Your Safety Read Before Lighting, Lighting Instructions, Log #5 Log #6 Log #3 Log #2

VGL18NRA, VGL30PRA, VGL18NRA, VGL18PRA, VGL24NRA, VGL24PRA, VGL30NRA, VGL30PRA specifications

Desa VGL series offers a range of innovative and efficient lighting solutions, primarily catering to various lighting needs in residential and commercial spaces. The models VGL18NRA, VGL18PRA, VGL24NRA, VGL24PRA, VGL30NRA, and VGL30PRA have been designed to provide high-performance lighting while maintaining energy efficiency.

Each model in the Desa VGL lineup features a robust design, making them suitable for diverse environments. The VGL18NRA and VGL18PRA models are known for their compact size, making them ideal for smaller spaces while still delivering powerful illumination. These models utilize advanced LED technology, ensuring a longer lifespan and lower energy consumption compared to traditional lighting solutions.

In contrast, the VGL24NRA and VGL24PRA models offer a step up in brightness and area coverage, making them perfect for medium-sized settings. With enhanced lumen output and superior optical design, these lights can effectively illuminate larger areas, ensuring safety and visibility.

The VGL30NRA and VGL30PRA models harness cutting-edge features, providing maximum brightness and adaptability for larger commercial spaces. These models come equipped with smart technologies, including dimming options and motion sensors, allowing for customized lighting solutions based on specific needs. This makes them an excellent choice for dynamic environments where lighting requirements may change throughout the day.

All models in the Desa VGL series are designed with durability in mind, often featuring weather-resistant enclosures suitable for outdoor installations. Additionally, these lights are easy to install and maintain, making them a practical choice for both professional installations and DIY projects.

In summary, the Desa VGL series, encompassing models VGL18NRA, VGL18PRA, VGL24NRA, VGL24PRA, VGL30NRA, and VGL30PRA, stands out for its versatility, energy efficiency, and advanced technology. These lights not only serve diverse lighting needs across various environments but also promise longevity and reduced energy costs, making them an ideal choice for forward-thinking consumers and businesses alike.