24
OPERATING FIREPLACE
For Your Safety Read Before Lighting (Cont.)
Lighting Instructions
To Turn Off Gas To Appliance
Manual Lighting Procedure
Optional
OPERATING FIREPLACE
Continued
C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.
D.Do not use this appliance if any part has been under water. Immediately call a qualified service techni- cian to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
LIGHTING
INSTRUCTIONS
1.STOP! Read the safety information above.
2.Open lower louver panel.
3.Turn off all electric power to the fireplace.
4.Push in gas control knob slightly and turn clockwise to “OFF”.
5.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information above. If you don't smell gas, go to the next step.
6.The pilot is located by the main burner and should not re- quire accessing for lighting.
7.Turn gas control knob counterclockwise to “PILOT”.
8.Push in gas control knob all the way and hold. Immedi- ately light the pilot by repeatedly depressing the piezo spark ignitor until a flame appears. Continue to hold for about one (1) minute after the pilot is lit. Release gas control knob and it will pop back. Pilot should remain lit. If it goes out, repeat steps 5 through 8.
•If gas control knob does not pop up when released, stop and immediately call your service technician or gas supplier.
•If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your service technician or gas supplier.
9.Turn on all electric power to the fireplace.
10.Turn gas control knob counterclockwise to “ON”.
11.This valve is equipped with a HI/LO feature. Set fireplace input as desired.
12.Close lower louver panel.
Gas Control |
| Variable Control Knob |
|
| |
Knob |
|
|
Piezo |
|
|
Ignitor | ILOT | IH |
O | O | |
| P | |
| F | N |
| F | |
|
| |
|
| LO |
Figure 50 - Control Valve |
|
|
TO TURN OFF GAS
TO APPLIANCE
1.Open lower louver panel.
2.Set selector switch in the OFF position to prevent draining battery.
3.Turn off all electrical power to the appliance if service is to be performed.
4.Push in gas control knob slightly and turn clockwise to “OFF”.
5.Close lower louver panel.
Shutting Off Burners Only (pilot stays lit)
You may shut off the burners and keep the pilot lit by doing one of the following:
1.Turn gas control knob clockwise to the PILOT position.
2.Set selector switch in the OFF position.
MANUAL LIGHTING
PROCEDURE
1.Remove glass door (see Removing/Replacing Glass Door, pages 21 and 22).
2.Follow steps 1 through 8 under Lighting Instructions.
3.Depress gas control knob and light pilot with match.
4.Keep gas control knob pressed in for 30 seconds after light- ing pilot. After 30 seconds, release gas control knob. Fol- low steps 10 through 14 under Lighting Instructions.
5.Replace glass door (see Removing/Replacing Glass Door, pages 21 and 22).
OPTIONAL HAND-HELD
REMOTE OPERATION
Note: All remote control accessories must be purchased sepa- rately (see Accessories, page 36). Follow instructions included with the remote control.
NOTICE: You must light the pilot before using the hand- held remote control unit. See Lighting Instructions.
1.After lighting, let pilot flame burn for about one minute. Turn control knob to ON position. Adjust flame adjust- ment knob anywhere between HI and LO. Slide the selec- tor switch to the REMOTE position (see Figure 51, page 25). Note: The burner may light if