OPERATING FIREPLACE

Continued

IMPORTANT: Do not leave the selector switch in the RE- MOTE or ON position when the pilot is not lit. This will drain the battery.

OPERATING FIREPLACE

25

Optional Hand-Held Remote Operation (Cont.)

 

 

2.

Press AUTO button to select this mode.

3.

Set the desired room temperature by pressing the TEMP

 

+ or - buttons.

Blower Control Knob

(Optional Accessory)

OFF

ON

Selector Switch

 

 

ON OFF REMOTE

 

 

 

 

 

in Remote

 

 

 

 

 

Position

 

 

 

 

 

 

 

 

 

 

Variable

Control Knob

N

 

L

 

O

 

I

 

 

O

T

F

O

H

O

 

 

F

 

 

LIP

 

 

 

 

 

 

 

Gas Control Knob in ON Position

4. Press the POWER and LOCK buttons together to turn off

the fireplace

Note: Do not leave the hand-held remote in the AUTO mode close to the fireplace. The radiant heat from the fireplace will turn off the fireplace. Ideally, place the hand-held remote in the center of the room facing towards the fireplace.

Note: Do not hold the hand-held remote for a long time. Body temperature will affect its operation in the AUTO mode.

Figure 51 - Setting the Selector Switch, Gas Control Knob, and Variable Control Knob for Remote Operation

ON/OFF SERIES MODEL GHRCB

Hold the control button on the hand-held remote until burner turns on. Hold the control button again until burner turns off (see Figure 52).

TO LOCK press both buttons on hand-held remote control until light stops flashing. Hand-held remote control is now locked. If the fire is on it will be turned off automatically. In the locked state, the light will not light up when any button is pressed.

TO UNLOCK press both buttons together on hand-held remote control until the light stops flashing. The hand-held remote is now unlocked.

Control Button

Turns Burners

On and Off

Figure 52 - On/Off Hand-Held Remote Control Unit GHRCB

THERMOSTAT SERIES MODEL GHRCTB

The hand-held remote can be operated using either the manual mode (MANU) or thermostatic mode (AUTO) (see Figure 53). To select Fahrenheit/Centigrade mode display, carefully press the ˚C/ ˚F mode button with the end of a paper clip or similar blunt object.

Manual Mode

1.Press the POWER and LOCK buttons together to turn on the hand-held remote control.

2.Press the MANU button to turn on the fireplace.

3.Press the POWER and LOCK buttons together to turn off the fireplace.

Auto (Thermostatic) Mode

1.Press the POWER and LOCK buttons together to turn on the hand-held remote control.

Digital Display

Shows

Temperature and

Settings

Turns Burners

On or Off

Decreases Room

Temperature in

AUTO Mode

Turns Hand-Held Remote On or Off and Allows You to Choose the Manual Setting

Selects Auto Setting

Increases Room

Temperature in AUTO

Mode

Locks System to Prevent Accidental Ignition

Figure 53 - Thermostat Hand-Held Remote Control Unit GHRCTB

Safety Features

When away from home for an extended period of time or as a child safety feature to prevent accidental ignition of the fire- place, the receiver ON/OFF/REMOTE switch should be in the OFF position.

Auto Shutoff Feature

1.If the average room temperature exceeds 82 degrees Fahr- enheit (28 degrees Centigrade), the hand-held remote con- trol will perform a safety override and shut the fireplace off. This feature is not available in the MANU mode.

2.The receiver continuously receives signals from the hand- held remote to control the room temperature. If the hand- held remote is misplaced, obstructed, or for any reason cannot transmit to the receiver, the receiver will shut off the fireplace after 8 minutes.

Key Pad Lock Feature

This feature allows the user to lock/unlock the keypad on the hand-held remote in the MANU or AUTO mode to prevent inadvertent operation (i.e. children operating the hand-held re- mote control, etc.). The keypad is locked in either on or off. Press the POWER and LOCK buttons together to turn the unit on or off.

For morevisit www..com

111923-01A

Page 25
Image 25
Desa (V)K36N, (V)K36P ON/OFF Series Model Ghrcb, Thermostat Series Model Ghrctb, Manual Mode, Auto Thermostatic Mode