OWNER’S MANUAL
INSTALLATION
Continued
Assembling Brass Trim (Brass trim shipped with mantel)
1. | Remove packaging from three remain- |
| ing pieces of brass trim. |
2. | Locate two adjusting plates with set |
| screws, and two shims in the hardware |
| packet. |
3. | Align shim under adjusting plate as |
| shown in Figure 15. |
4. | Slide one end of adjusting plate/shim |
| in slot on mitered edge of top brass trim |
| (see Figure 15). |
5. | Slide other end of adjusting plate/shim |
| in slot on mitered edge of side brass |
| trim (see Figure 15). |
6. | While firmly holding edges of brass |
| trim together, tighten both set screws |
| on the adjusting plate with slotted |
| screwdriver. |
INSTALLING BLOWER ACCESSORY GA3450T
Removing Upper Louver
Assembly
To install the blower accessory, you must first remove the upper louver assembly.
1.Lift screen off heater.
2.Remove 4 screws from louver assem- bly (see Figure 16). Save these screws.
3.Pull louver assembly straight out from the cabinet. Be careful not to scratch the paint. Set louver assembly and screws aside.
Blower Bracket
Mounting Holes
Branch
Shoulder Support
Screw
Remove
Screw
Valve
Cover
Shield 2
1
Bottom Louver
SnapAssembly
Bushings
Figure 17 - Removing Valve Cover Shield
7. | Repeat steps 1 through 6 for other corner. |
8. | Set brass assembly aside for later in- |
| stallation. |
Top Brass Trim
SetSlot
Screws
Mitered
Shim Edge
| Side |
Adjusting | Brass |
Trim |
Plate
Slot
Figure 15 - Assembling Brass Trim
Upper Louver
Assembly
Brass Screws
Figure 16 - Removing Upper Louver Assembly
Removing Valve Cover Shield
1.Open bottom louver assembly by swinging the assembly down (see Fig- ure 17).
2.Using short Phillips screwdriver, re- move the screw under the center of the branch support. Rotate valve cover shield clockwise and slide out. IMPORTANT: Do not remove shoul- der screw on the left side of valve cover shield. Slide the valve cover shield off of the shoulder screw (see Figure 17).
Note: If you do not have a short Phillips screwdriver, the screen, log set, and branch support must be removed so a longer screwdriver may be used. See Connecting Fireplace To Gas Sup- ply, page 15 and follow step 2.
Installing Blower Assembly
CAUTION: Label all wires prior to disconnection when ser- vicing controls. Wiring errors can cause improper and danger- ous operation.
CAUTION: Verify proper op- eration after servicing.
Note: If you are using a mantel with your heater, use the following instructions. If your heater is
1.Install snap bushings found in hardware kit into both holes in rear of valve cover shield.
2.Make sure the wire harness is firmly connected to the terminals on the blower bracket assembly.
3.Note the wire locations on back of AUTO/OFF/ON switch. The terminals on back of switch are numbered 1, 2, and 3. Carefully remove red wire from terminal 1 and blue wire from terminal 3. Black wire can remain on middle terminal 2 (see Figure 18, page 12).
Continued
107030 | 11 |