INSTALLATION

CHECK GAS TYPEINSTALLATION ITEMSLOCATING FIREPLACEManual backgroundManual background ® VMH26TPB

COMPACT CLASSIC HEARTH® FIREPLACE

INSTALLATION

NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your pri- mary heating system. Do not in- stall this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circu- late the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.

Manual background WARNING: A qualified ser- vice person must install fireplace. Follow all local codes.

Manual background WARNING: Never install the fireplace

in a bedroom or a bathroom

in a recreational vehicle

where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the fireplace

as a fireplace insert

in high traffic areas

in windy or drafty areas

Manual background CAUTION: This fireplace cre- ates warm air currents. These cur- rents move heat to wall surfaces next to fireplace. Installing fire- place next to vinyl or cloth wall coverings or operating fireplace where impurities (such as, but not limited to, tobacco smoke, aromatic candles, cleaning flu- ids, oil or kerosene lamps, etc.) in the air exist, may discolor walls or cause odors.

IMPORTANT:Vent-freefireplacesaddmois- ture to the air. Although this is beneficial, installing fireplace in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, pages 5 through 7.

Note: Your Vanguard fireplace is designed to be used in zero clearance installations. Wall or framing material can be placed directly against any exterior surface of your fireplace, except where standoff spacers are integrally attached. If standoff spacers are attached to your fire- place, these spacers can be placed directly against wall or framing materials.

Use the dimensions shown for rough open- ings to create the easiest installation (see Built-In Fireplace Installation, page 9).

CHECK GAS TYPE

Use only propane/LP gas. If your gas supply is not propane/LP, do not install fireplace. Call dealer where you bought fireplace for proper type fireplace.

INSTALLATION ITEMS

Before installing fireplace, make sure you have the items listed below.

external regulator (supplied by installer)

piping (check local codes)

sealant (resistant to propane/LP gas)

equipment shutoff valve *

test gauge connection*

ground joint union

sediment trap

tee joint

pipe wrench

*A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Pur- chase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 26.

Note: If desired, purchase a four-sided brass trim kit for built-in installations. See Acces- sories, page 26.

LOCATING FIREPLACE

Manual background WARNING: Maintain the mini- mum clearances shown in Fig- ures 7 and 8. If you can, provide greater clearances from floor, ceiling, and joining wall.

You can recess firebox into the wall. You can also position fireplace in the optional cabinet or corner mantels. IMPORTANT: Only use optional cabinet or corner mantels specified in this manual. Purchase the op- tional mantel from your dealer (see Acces- sories, page 26).

 

CEILING

 

36"

 

Minimum

6"

 

Minimum

 

From

 

Sides Of

 

Fireplace

 

Left

Right

Side

Side

FLOOR

0" Minimum To Top Surface Of Carpeting, Tile Or Other Combustible Material

Figure 7 - Mounting Clearances As Viewed

From Front of Fireplace Shown Built-In

the Wall

CEILING

Top Of

Mantel Can

Be Flush36"

Minimum

With Wall

Right

Side

Left

Side

0" Minimum To Top Surface Of Carpeting, Tile Or Other Combustible Material

Figure 8 - Mounting Clearances As Viewed From Front of Fireplace Shown with Optional Mantel

Note: When installing fireplace directly on carpeting, tile or other combustible mate- rial, other than wood flooring, the fireplace shall be installed on a metal or wood panel extending the full width and depth of the fireplace.