Installation Items Needed

OWNER’S MANUAL

INSTALLATION

Continued

CONNECTING EQUIPMENT SHUTOFF VALVE TO HEATER CONTROL

Installation Items Needed

Phillips screwdriver

sealant (resistant to propane/LP gas, not provided)

valve should be accessible. CAUTION: Avoid damage to regulator. Hold gas regulator with wrench when connecting it to gas piping and/or fittings.

4.Apply pipe joint sealant lightly to male threads of gas connector attached to flexible gas line/equipment shutoff valve (see Figure 26).

5.Check all gas connections for leaks. See Checking Gas Connections, page 16.

6.Replace branch support back into fire- place. Feed flexible gas line into fire- place base area while replacing branch support. Make sure the entire flexible gas line is in fireplace base area. Reat- tach branch support to fireplace with screws removed in step 2.

1.Remove fireplace screen. Remove two screws that hold fireplace screen in place for shipping. These screws are located near top of screen. Discard screws. Lift fireplace screen up and pull out to remove.

2.Remove screws that attach branch sup- port to fireplace (see Figure 25). Care- fully lift up branch support and remove from fireplace (see Figure 25).

3.Route flexible gas line included from fireplace control to equipment shutoff valve through side or rear access holes in outer casing.

NOTICE: Most building codes do not permit concealed gas con- nections. A flexible gas line is provided to allow accessibility from the fireplace (see Figure 25). The flexible gas supply line con- nection to the equipment shutoff

Branch

Support

Shoulder

Screw

Flexible

Gas

Line

Screen

Figure 25 - Removing Branch Support From Fireplace

valve should be accessible.

To Fireplace

Gas Regulator

Manual background

Flexible Gas Line from Fireplace Gas Regulator

Equipment Shutoff Valve Provided by Installer

To External

 

 

Regulator

Figure 26 - Attaching Flexible Gas Line to Equipment Shutoff Valve

Continued

107030

15

Page 15
Image 15
Desa VMH26TPB 14 installation manual Installation Items Needed, Continued, valve should be accessible