AIR FOR COMBUSTION AND VENTILATION

Ventilation Air

INSTALLATION

AIR FOR COMBUSTION AND VENTILATION

Continued

VENTILATION AIR

Ventilation Air From Inside Building

This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove door into adjoining room (see option 3, Figure 2). Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

Ventilation Air From Outdoors

Ventilated

Outlet Attic

Air

Outlet

Air

Inlet

Air

To Attic

To

Crawl

Space

Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code, ANSI Z223.1/ NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostat-controlled power vent. Heated air entering the attic will activate the power vent.

Inlet Air

 

Ventilated

 

Crawl Space

 

 

Figure 3 - Ventilation Air from Outdoors

INSTALLATION

NOTICE: This heater is intended for use as supple- mental heat. Use this heater along with your primary heating system. Do not install this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage,

Ventilation

Grills

Into Adjoining

12"

Ventilation Grills Into Adjoining Room,

you can use this heater as your primary heat source.

WARNING: A qualified service person must in-

Room,

Or

Option 2

stall heater. Follow all local codes.

Option 1

Remove

Door into Adjoining Room, Option 3

12"

Figure 2 - Ventilation Air from Inside Building

For more

NOTICE: State or local codes may only allow opera- tion of this appliance in a vented configuration. Check your state or local codes.

WARNING: Before installing in a solid fuel burn- ing fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner. Creosote will ignite if highly heated. A dirty chimney flue may create and distribute soot within the house. Inspect chimney flue for damage. If damaged, repair flue and firebox before operating heater.

visit www. .com

111115-01D

Page 6
Image 6
Desa VML27PR Installation, Ventilation AIR, Ventilation Air From Inside Building, Ventilation Air From Outdoors

VML27PR specifications

Desa VML27PR is a cutting-edge development that represents a significant leap forward in efficient living and sustainable technology. This modern residential complex is designed with both aesthetics and functionality in mind, making it a prime choice for contemporary urban dwellers.

One of the standout features of Desa VML27PR is its commitment to energy efficiency. The buildings are equipped with solar panels that harness renewable energy, significantly reducing reliance on non-renewable power sources. This integration not only lowers utility bills for residents but also contributes to a lower carbon footprint, aligning with global sustainable development goals.

The architecture of Desa VML27PR is marked by its contemporary design, featuring open floor plans and large windows that maximize natural light and ventilation. The use of eco-friendly construction materials further enhances the sustainability aspect, ensuring that the development minimizes its impact on the environment while providing a comfortable living space.

Safety and security are of paramount importance in Desa VML27PR. The complex is equipped with state-of-the-art security systems, including video surveillance and controlled access points, giving residents peace of mind. Additionally, the premises are well-lit and feature landscaped green spaces, promoting a sense of community while ensuring a safe environment for families.

Another significant characteristic of Desa VML27PR is its emphasis on smart technology integration. Homes are equipped with smart appliances and systems that allow residents to control lighting, heating, and security from their mobile devices. This not only enhances convenience but also promotes energy savings by enabling users to monitor and manage their usage effectively.

Desa VML27PR also boasts a variety of communal facilities designed to foster community engagement. These include recreational areas, fitness centers, and coworking spaces that encourage interaction among residents, making it an ideal place for those seeking a vibrant social life.

In conclusion, Desa VML27PR exemplifies the future of urban living, combining sustainability, modern design, advanced technology, and community-focused amenities. It stands as a model for future residential developments, showcasing how contemporary living can harmoniously coexist with environmental responsibility and community engagement. Whether seeking a home for a growing family or a sophisticated living space for professionals, Desa VML27PR is equipped to meet diverse needs, making it a premier choice in today’s real estate market.