Desa VN1800IT, VN1800C Trouble Shooting, Continued, Observed, Possible, Problem, Cause, Remedy

Models: VN1800C VN3000C VN1800IT VN2550IT

1 40
Download 40 pages 9.48 Kb
Page 28
Image 28
TROUBLE-

TROUBLE-

SHOOTING

Continued

28

OBSERVED

POSSIBLE

 

 

PROBLEM

CAUSE

REMEDY

Burner(s) does not

1.

Burner orifice(s) is

1.

Clean burner orifice(s)

light after ODS/pilot is

 

clogged.

 

(see Cleaning and

lit.

 

 

 

Maintenance, page 26) or

 

 

 

 

replace burner orifice(s).

 

2.

Burner orifice(s)

2.

Replace burner orifice(s).

 

 

diameter is too small.

 

 

 

3.

Inlet gas pressure is too

3.

Contact local natural gas

 

 

low.

 

company.

 

 

 

 

 

Delayed ignition of

1.

Manifold pressure is too

1.

Contact local natural gas

burner(s)

 

low.

 

company.

 

2.

Burner orifice(s) is

2.

Clean burner orifice(s)

 

 

clogged.

 

(see Cleaning and

 

 

 

 

Maintenance, page 26) or

 

 

 

 

replace burner orifice(s).

 

 

 

 

 

Burner backfiring

1.

Burner orifice(s) is

1.

Clean burner orifice(s)

during combustion.

 

clogged or damaged.

 

(see Cleaning and

 

 

 

 

Maintenance, page 26) or

 

 

 

 

replace burner orifice(s).

 

2.

Burner damaged.

2.

Replace burner.

 

3.

Gas regulator defective.

3.

Replace gas regulator.

 

 

 

 

 

Burner plaque(s) does

1.

Plaque damaged

1.

Replace burner.

not glow.

2.

Inlet gas pressure is too

2.

Contact local natural gas

 

 

low.

 

company.

 

3.

Control knob set be-

3.

Turn control knob until it

 

 

tween locked positions.

 

locks at desired setting.

 

 

 

 

 

Slight smoke or odor

1.

Residues from manu-

1.

Problem will stop after a

during initial opera-

 

facturing processes.

 

few hours of operation.

tion

 

 

 

 

 

 

 

 

 

Heater produces a

1.

Metal expanding while

1.

This is common with

clicking/ticking noise

 

heating or contracting

 

most heaters. If noise is

just after burner is lit or

 

while cooling.

 

excessive, contact

shut off.

 

 

 

qualified service person.

100750

Page 28
Image 28
Desa VN1800IT, VN1800C, VN2550IT Trouble Shooting, Continued, Observed, Possible, Problem, Cause, Remedy, see Cleaning and