VN2550IT

BTU (Variable)

6,600-18,000

7,000-25,500

Type Gas

Natural Only

Natural Only

Ignition

Piezo

Piezo

Pressure Regulator Setting

6" W.C.

6" W.C.

Inlet Gas Pressure (in. of water)

 

Maximum

10.5"

10.5"

Minimum

7"

7"

Dimensions, Inches (H x W x D)

 

Heater

23.5 x 18.5 x 8

23.5 x 25.9 x 8

Carton

25.8 x 21.3 x 10.1

25.8 x 28.7 x 10.1

Weight (pounds)

 

 

Heater

24

32

Shipping

29

38

 

 

 

 

VN1800C

VN3000C

BTU (Variable)

6,600/12,000/18,000

6,600/18,000/30,000

Type Gas

Natural Only

Natural Only

Ignition

Piezo

Piezo

Pressure Regulator Setting

6" W.C.

6" W.C.

Inlet Gas Pressure (in. of water)

 

Maximum

10.5"

10.5"

Minimum

7"

7"

Dimensions, Inches (H x W x D)

 

Heater

23.5 x 18.5 x 8

23.5 x 25.9 x 8

Carton

25.8 x 21.3 x 10.1

25.8 x 28.7 x 10.1

Weight (pounds)

 

 

Heater

22

30

Shipping

27

36

You can purchase a service manual from the address listed on the back page of this manual. Send a check for $5.00 payable to DESA International.

When gas pressure is too low

pilot will not stay lit

burner(s) will have delayed ignition

heater will not produce specified heat

When gas quality is bad

pilot will not stay lit

burner(s) will produce flames and soot

heater will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your local natural gas supplier.

100750