Desa VN2550IT, VN1800IT, VN1800C, VN3000C Installing To Wall, Continued, Thermostat Sensing Bulb

Models: VN1800C VN3000C VN1800IT VN2550IT

1 40
Download 40 pages 9.48 Kb
Page 10
Image 10
INSTALLING TO WALL
Thermostat
Sensing Bulb

INSTALLING TO WALL

Continued

10

For convenience and efficiency, install heater

where there is easy access for operation, inspection, and service

in coldest part of room

An optional fan kit is available from your dealer. See Accessories, page 31. If planning to use fan, locate heater near an electrical outlet.

CEILING

 

36"

8"

Minimum

 

Minimum

 

From

 

Sides Of

 

Heater

 

Left

Right

Side

Side

 

3" Minimum To Top Surface

FLOOR

Of Carpeting, Tile Or Other

Combustible Material

Figure 4 - Mounting Clearances As Viewed From Front of Heater

THERMOSTAT SENSING BULB

(Models VN1800IT and VN2550IT Only)

The thermostat sensing bulb has been placed inside the heater for protection during shipping.

Locating Thermostat Sensing Bulb

1.Remove front panel of heater (see Figure 7, page 11).

2.Locate thermostat sensing bulb just under the burner assembly.

IMPORTANT: Attach thermostat sensing bulb to the back of heater for proper operation.

Attaching Thermostat Sensing Bulb

1.Remove thermostat sensing bulb from holders inside heater. Route through slot opening in bottom of heater.

2.Place clamp on thermostat sensing bulb as shown in Figure 5. Clamp is pro- vided in hardware package.

3.Snap clamp into upper mounting hole as shown in Figure 5. Mounting hole is located on lower left edge on back of heater. Make sure the thermostat sensing

bulb is pointing up.

THERMOSTAT SENSING BULB Clamp

Figure 5 - Attaching Thermostat Sensing Bulb

100750

Page 10
Image 10
Desa VN2550IT, VN1800IT, VN1800C, VN3000C installation manual Installing To Wall, Continued, Thermostat Sensing Bulb