Desa VN20BTA, VP30BTA Troubleshooting, Continued, Observed Problem, Possible Cause, Remedy

Models: VN20BTA VN30BTA VP20BTA VP30BTA

1 24
Download 24 pages 58.28 Kb
Page 19
Image 19
(see Cleaning and Mainte-

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

 

 

Yellow flame during burner

1.

Not enough air

1.

Check burner for dirt and

combustion

 

 

 

debris. If found, clean burner

 

 

 

 

(see Cleaning and Mainte-

 

2.

Gas regulator defective

2.

nance, page 16)

 

Replace gas regulator

 

3.

Clogged or dirty burner

3.

Clean burner (see Cleaning

 

 

 

 

and Maintenance, page 16)

 

Slight smoke or odor during initial

1.

Residues from manufacturing

1.

Problem will stop after a few

operation

 

processes

 

hours of operation

 

 

 

 

 

 

Heater produces a whistling noise

1.

Turning control knob to posi-

1.

Turn control knob to position 1

when burner is lit

2.

tion 5 when burner is cold

2.

and let warm up for a minute

 

Air in gas line

Operate burner until air is

 

 

 

 

removed from line. Have gas

 

 

 

 

line checked by local natural

 

3.

Air passageways on heater

3.

or propane/LP gas company

 

Observe minimum installation

 

4.

blocked

4.

clearances (see Figure 4, page 8)

 

Dirty or partially clogged

Clean burner (see Cleaning

 

 

burner orifice

 

and Maintenance, page 16) or

 

 

 

 

replace burner orifice

 

 

 

 

 

 

White powder residue forming

1.

When heated, vapors from

1.

Turn heater off when using

within burner box or on adjacent

 

furniture polish, wax, carpet

 

furniture polish, wax, carpet

walls or furniture

 

cleaner, etc., may turn into

 

cleaners or similar products

 

 

white powder residue

 

 

 

 

 

 

 

 

 

Heater produces a clicking/tick-

1.

Metal expanding while heating

1.

This is normal with most heat-

ing noise just after burner is lit

 

or contracting while cooling

 

ers. If noise is excessive, contact

or shut off

 

 

 

qualified service person

 

Heater shuts off in use (ODS

1.

Not enough fresh air is avail-

1.

Open window and/or door for

operates)

2.

able

2.

ventilation

 

Low line pressure

Contact local natural or pro-

 

3.

ODS/pilot is partially

3.

pane/LP gas company

 

Clean ODS/pilot (see Cleaning

 

 

clogged

 

and Maintenance, page 16)

113061-01F

www.desatech.com

19

Page 19
Image 19
Desa VN20BTA, VP30BTA Troubleshooting, Continued, Observed Problem, Possible Cause, Remedy, see Cleaning and Mainte