INSTALLATION

6

INSTALLATION

Check Gas Type

Installation Items

Locating Heater

INSTALLATION

NOTICE: This heater is intended for use as supple- mental heat. Use this heater along with your primary heating system. Do not install this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.

CHECK GAS TYPE WARNING: A qualified service person must in- stall heater. Follow all local codes.

CHECK GAS TYPE

Use only the correct type of gas (natural or propane/LP). If your gas supply is not the correct gas type, do not install heater. Call dealer where you bought heater for proper type heater.

INSTALLATION ITEMS

Before installing heater, make sure you have the items listed below.

for propane/LP gas, external regulator (supplied by installer)

piping (check local codes)

sealant (resistant to propane/LP gas)

equipment shutoff valve *

ground joint union

sediment trap

tee joint

pipe wrench

for natural gas, test gauge connection*

*A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessory, page 28.

LOCATING HEATER

This heater is designed to be mounted on a wall.

INSTALLATION ITEMS WARNING: Maintain the minimum clearances shown in Figure 4. If you can, provide greater clear- ances from floor, ceiling, and joining wall.

LOCATING HEATER WARNING: Never install the heater

in a bathroom (10,000 Btu/hr only. 6,000 Btu/hr mod- els are allowed in a bathroom. Check local codes.)

in a recreational vehicle

where curtains, furniture, clothing, or other flam- mable objects are less than 36 inches from the front, top, or sides of the heater

as a fireplace insert

in high traffic areas

in windy or drafty areas

Manual background CAUTION: This heater creates warm air currents. These currents move heat to wall surfaces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as, but not limited to, tobacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls or cause odors.

IMPORTANT: Vent-free heaters add moisture to the air. Al- though this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, pages 4 through 6.

Manual background CAUTION: If you install the heater in a home garage

heater pilot and burner must be at least 18 inches above floor

locate heater where moving vehicle will not hit it

For convenience and efficiency, install heater

where there is easy access for operation, inspection, and service

in coldest part of room

 

CEILING

6" Blueflame

36"

Minimum

8" Plaque

 

Minimum

 

From

 

Sides Of

 

Heater

 

 

Right

Left

Side

Side

 

3" Minimum To Top

Surface Of Carpeting,

Tile Or Other

Combustible Material

Figure 4 - Mounting Clearances As Viewed From Front of Heater

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundFor moreManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundvisit www.Manual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background