6.In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4, page 21.

Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot as- sembly. There is a small pilot air inlet hole about 2" from where the pilot flame comes out of the pilot assembly (see Figure 38). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

Pilot

Ports/

Slots

Assembly

 

Burner

Tube

Pilot Air

Inlet Hole

Figure 38 - Pilot Inlet Air Hole

LOGS

If you remove logs for cleaning, refer to Install- ing Logs, page 16, to properly replace logs.

Replace log(s) if broken or chipped (dime-sized or larger).

Wiring Diagram

Note: For proper operation of optional accessories, the wires from the switch to the control must be connected exactly as shown.

AUTO

OFF

ON

 

 

 

Thermopile

 

Specifications

Model VSGF33NRC

 

 

Rating (Variable)

21,500/33,000 Btu/Hr

Type Gas

Natural Gas Only

Ignition

Piezo

Pressure Manifold

3.5" W.C.

• Inlet Gas Pressure (in. of water)

 

Maximum

10.5"

 

Minimum*

5"

 

Shipping Weight

122 lbs.

* For input adjustment

 

 

Model VSGF33PRC

 

 

Rating (Variable)

21,500/33,000 Btu/Hr

Type Gas

Propant/LP Only

Ignition

Piezo

Pressure Manifold

7.9" W.C.

• Inlet Gas Pressure (in. of water)

 

Maximum

13"

 

Minimum*

11"

 

Shipping Weight

122 lbs.