CLEANING AND
MAINTENANCE
Continued
6.In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4, page 21.
Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot as- sembly. There is a small pilot air inlet hole about 2" from where the pilot flame comes out of the pilot assembly (see Figure 38). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.
Pilot | Ports/ | |
Slots | ||
Assembly | ||
|
Burner
Tube
Pilot Air
Inlet Hole
Figure 38 - Pilot Inlet Air Hole
LOGS
•If you remove logs for cleaning, refer to Install- ing Logs, page 16, to properly replace logs.
•Replace log(s) if broken or chipped
Wiring Diagram
Note: For proper operation of optional accessories, the wires from the switch to the control must be connected exactly as shown.
AUTO
OFF
ON
|
|
| Thermopile |
| Specifications | ||
Model VSGF33NRC |
|
| |
• | Rating (Variable) | 21,500/33,000 Btu/Hr | |
• | Type Gas | Natural Gas Only | |
• | Ignition | Piezo | |
• | Pressure Manifold | 3.5" W.C. | |
• Inlet Gas Pressure (in. of water) | |||
| Maximum | 10.5" |
|
• | Minimum* | 5" |
|
Shipping Weight | 122 lbs. | ||
* For input adjustment |
|
| |
Model VSGF33PRC |
|
| |
• | Rating (Variable) | 21,500/33,000 Btu/Hr | |
• | Type Gas | Propant/LP Only | |
• | Ignition | Piezo | |
• | Pressure Manifold | 7.9" W.C. | |
• Inlet Gas Pressure (in. of water) | |||
| Maximum | 13" |
|
• | Minimum* | 11" |
|
Shipping Weight | 122 lbs. |
* For input adjustment
22 | www.desatech.com |