Installation

Continued

Rail

Hood

Screw

Figure 5 - Installing Hood

Assembling and attaching OPTIONAL perimeter trim (Included with Mantel Accessory)

IMPORTANT: If you are recessing the firebox in a wall, do not attach trim at this time. See Built-In Fireplace Installation, page 11.

Note: The instructions below show assembling and attaching trim to fireplace.

1.Remove packaging from three pieces of trim.

2.Locate four screws, two adjusting plates with set screws, and two shims in the hard- ware packet.

3.Align shim under adjusting plate as shown in Figure 6.

4.Slide one end of adjusting plate/shim in slot on mitered edge of top trim (see Figure 6).

5.Slide other end of adjusting plate/shim in slot on mitered edge of side trim (see Figure 6).

6.While firmly holding edges of trim together, tighten both set screws on the adjusting plate with slotted screwdriver.

7.Repeat steps 1 through 6 for other side.

8.Tighten trim hanging screws (#10 x 6.25 shoul- der) into holes in cabinets. Place the assembled trim onto fireplace cabinet.Align hanging notches on trim with hanging screws on side of fireplace (see Figure 7). Push trim firmly into place, sliding hanging notches over hanging screws.

 

Set Screws

Side Trim Adjusting

Top

Plate

Trim

Mitered

Shim Edge

Mitered Slot

Slot Edge

Figure 6 - Assembling Perimeter Trim

Trim

Hanging

Screws

Hanging Notches on Trim

Assembled

Trim

Figure 7 - Attaching Perimeter Trim to

Fireplace

INSTALLATION CLEARANCES

WARNING: Maintain the minimum clearances. If you can, provide greater clearances from floor, ceiling, and adjoining wall.

Carefully follow the instructions below. This will ensure safe installation.

MinimumClearances ForSideCombustible

Material, Side Wall, and Ceiling

A. Clearances from the side of the fireplace cabinet to any combustible material and wall should follow diagram in Figure 8.

Example: The face of a mantel, bookshelf, etc. is made of combustible material and protrudes 3 1/2" from the wall. This combus- tible material must be 4" from the side of the fireplace opening (see Figure 8).

B. Clearances from the top of the fireplace opening to the ceiling should not be less than 42".

MINIMUM CLEARANCE TO

COMBUSTIBLE MATERIALS

Top

Left and

Bottom

 

Right Sides

and Rear

0"

16"

0"

 

Example

 

 

 

*

*Minimum 16" from SideWall

Figure 8 - Minimum Clearance for

Combustible to Wall