TROUBLESHOOTING

Continued

WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Fol- low the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating fireplace where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

 

Fireplace produces unwanted

1. Heater burning vapors from

1.

Open window to ventilate room.

odors

 

paint, hair spray, glues,

 

Stop using odor causing prod-

 

 

cleaners, chemicals, new

 

ucts while heater is running

 

 

carpet, etc. (See IMPOR-

 

 

 

 

2.

TANT statement above)

2.

Refill supply tank (propane/LP

 

Low fuel supply (propane/LP

 

3.

only)

3.

only)

 

Gas leak. See Warning

Locate and correct all leaks

 

 

statement above

 

(see Checking Gas Connec-

 

 

 

 

tions, page 15)

 

 

 

 

 

Fireplace shuts off in use (ODS

1. Not enough fresh air is

1.

Open window and/or door for

operates)

2.

available

2.

ventilation

 

Low line pressure

Contact local natural or pro-

 

3.

ODS/pilot is partially

3.

pane/LP gas company

 

Clean ODS/pilot (see Cleaning

 

 

clogged

 

and Maintenance, page 21)

 

 

 

 

 

Gas odor even when control knob

1. Gas leak. See Warning

1.

Locate and correct all leaks

is in OFF position

 

statement above

 

(see Checking Gas Connec-

 

2.

Control valve or gas control

2.

tions, page 15)

 

Replace control valve or gas

 

 

defective

 

control

 

Gas odor during combustion

1. Foreign matter between

1.

Take apart gas tubing and

 

2.

control valve and burner

2.

remove foreign matter

 

Gas leak. See Warning

Locate and correct all leaks

 

 

statement above

 

(see Checking Gas Connec-

 

 

 

 

tions, page 15)

26

www.desatech.com

119304-01A

Page 26
Image 26
Desa VSGF33NRC, VSGF33PRC installation manual Gas leak. See Warning, Statement above