OPERATIng fireplace
Continued
TO TURN OFF GAS
TO APPLIANCE
1.Turn off the wall switch.
2.Turn off all electric power to the appliance if service is to be performed.
3.Open lower louver panel.
4.Turn equipment shutoff valve clockwise to OFF. Do not force.
5.Close lower louver panel.
OPTIONAL REMOTE
OPERATION
Note: The WRC receiver and
1.Turn equipment shutoff valve to ON posi- tion. You can now turn the burner on and off with the
IMPORTANT: Be sure to press the ON/OFF buttons on the
2.Press the ON/OFF button to turn the burner on and off.
operating optional blower accessory
Locate the blower controls by opening the lower louver panel on the fireplace. Blower controls are located on the left side of the switch bracket to the left just inside the louver panel.
The BK manual blower and the BKT thermo-
Note for BKT Only: If you are using BKT blower with optional thermostat (wall mounted or remote control) for the fireplace, your fire- place and blower will not turn on and off at the same time. The fireplace may run for several minutes before the blower turns on. After the heater modulates to the pilot position, the blow- er will continue to run. The blower will shut off after the firebox temperature decreases.
The blower helps distribute heated air from the fireplace. Periodically check the louvers of the firebox and remove any dust, dirt, or other obstructions that will hinder the flow of air.
Inspecting Burners
Check pilot flame pattern and burner flame pat- terns often.
PILOT Assembly
The pilot assembly is factory preset for the proper flame. Alterations may have occurred during ship- ping and handling. The pilot is located on the back right hand side of the burner.
The flame must envelope 1/4" of top of the ignitor/ sensor and grounding stem.
If your pilot assembly does not meet these re- quirements:
•Turn the adjustment screw marked PILOT clockwise to decrease or counterclockwise to increase the flame to proper size (see Figure 48, page 28). Do not remove the adjustment screw.
•see Troubleshooting, page 31
Sensing
Pilot Rod Burner
Ignitor/
Sensor
Figure 50 - Correct Pilot Flame Pattern
BURNER FLAME PATTERN
Burner flames will be steady; not lifting or floating. Flame patterns will be different from unit to unit and will vary depending on installation type and weather conditions.
If the vent configuration is installed incorrectly, the flames will lift or "ghost". This can be danger- ous. Inspect the flames after installation to ensure proper installation and performance.
Figure 51 shows a typical flame pattern.
If burner flame pattern differs from that described:
•turn fireplace off (see To Turn Off Gas to Ap- pliance)
•see Troubleshooting, page 31
Figure 51 - Typical Flame Pattern
www.desatech.com | 29 |