Desa (V)T36EPA Cleaning and Maintenance, Troubleshooting, venting system, Remedy

Models: (V)T36EPA

1 40
Download 40 pages 51.96 Kb
Page 31
Image 31
venting system

Cleaning and Maintenance

Continued

venting system

3. Check for evidence of excessive condensation.

Conduct annual inspection of the venting system

Continuous condensation can cause corrosion

following these guidelines:

of caps, pipes, and fittings and can be caused

1. Check areas of venting system that are ex-

by having excessive lateral runs, too many

elbows, or exterior portions of the system

posed to the weather for corrosion (rust spots

being exposed to cold weather.

or streaks and, in extreme cases, holes). Have

4. Inspect joints to verify that no pipe section or

these items replaced immediately by a quali-

fied service person.

fitting has been disturbed and loosened. Check

2. Remove the vent cap and shine a flashlight

mechanical supports such as wall straps for

rigidity.

into the vent. Remove any foreign material.

 

Troubleshooting

Troubleshooting WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater.

OBSERVED PROBLEM POSSIBLE CAUSE CAUTION: Never use a wire, needle, or similar object to clean pilot. This can damage pilot unit.

The two most common causes of a malfunctioning gas appliance are:

1.Loose wiring connections

2.Construction debris clogging the pilot and/or gas control valve filter

Note: Before troubleshooting the system, make sure the gas shutoff valve is ON.

OBSERVED PROBLEM POSSIBLE CAUSE

REMEDY

Ignitor will not spark or pilot will not light

1.No gas supply, or shutoff valve is OFF

2.Air in gas line

3.Construction debris clogging pilot orifice

4.Low gas pressure

5.Kinked pilot line

6.Control valve knob is not opening

7.No power to unit or the igni- tion module or power trans- former is bad

8.Vent damper not fully open

1.Check to see if you have gas supply and that equipment shutoff valve is opened

2.Repeat lighting procedure sev- eral times to purge all air out of lines. If after repeated attempts appliance does not light, call for qualified service and repair.

3.Remove debris and dirt, in- spect and clean any other possible obstructions

4.Contact your gas supplier to check pressure

5.Have a qualified technician replace pilot line

6.Replace control valve (Refer to

Replacement Parts, page 38)

7.Check that main power is on and that all wire connections are made correctly to the ignition model (see Wiring Diagram, page 27). Check for 24 VAC at the secondary side of the trans- former. If 24 VAC is present, and module does not operate, have module replaced otherwise have transformer replaced.

8.Open vent damper until fully locked in OPEN position

111251-01E