Desa (V)T36EPA SERIES, (V)T36ENA SERIES Venting Installation Instructions, Continued, Vertical

Models: (V)T36ENA SERIES, (V)T36EPA SERIES (V)T36EPA SERIES, (V)T36ENA SERIES

1 38
Download 38 pages 46.18 Kb
Page 10
Image 10
Vertical (V)

10

VENTING INSTALLATION INSTRUCTIONS

Installation Planning (Cont.)

VENTING INSTALLATION

INSTRUCTIONS

Continued

GROUND FLOOR INSTALLATION

Recommended Applications:

Minimum Pipe Overlap 11/4"

Siding Standoff

Screws

Installation using cabinet surrounds

Through the wall using round or square termination (up to 12" horizontal pipe)

NOT FOR CORNER INSTALLATION

Direct Vent

Pipe

Wall

Firestop

Adjustable

Pipe 12" Max.

Horizontal High

Wind Square

Termination

45° Elbow

Maintain 1"

Minimum Air

Space Around

Outer Pipe When

Penetrating a Wall

10" x 10" Framed Opening

Horizontal (H) High Wind Termination

Apply Mastic to Outside Edge of Standoff

Exterior Wall with Vinyl Siding

Wall Firestop 32" min.

Square Termination

Vertical (V)Horizontal (H)
32" min.17" max.

45° Elbow

Exterior Portion of Wall

 

Wall

Firestop (Round

 

Termination Only)

Figure 13 - Typical Horizontal Termination Cap Mounting with Additional Siding Standoff Installed

Horizontal Termination Configurations

Figures 14 through 18 show different configurations and alternatives for venting with horizontal termination. Each figure includes a chart with critical minimum and maximum dimensions which MUST be met. IMPORTANT: Remember that a horizontal run of venting must have a 1/4" rise for every 12" of run toward the termination.

17" max. WARNING: Never run vent downward as this may cause excessive temperatures which could cause a fire. Operation of improperly installed and main- tained venting system could result in serious injury, property damage or loss of life.

Firestop

Slide Ring

Round

Termination

Over Elbow to

Cap

Complete

 

Connection

 

Round Termination

(Kit HTK Shown)

Figure 14 - Horizontal Termination Configuration for Square and Round Terminations

Horizontal Termination ConfigurationsRound TerminationManual backgroundManual backgroundManual backgroundForManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background.Manual backgroundManual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual background