24
OPERATING FIREPLACE
Lighting Instructions (Cont.)
To Turn Off Gas To Appliance
Manual Lighting Procedure
Optional
OPERATING FIREPLACE |
| |
Continued |
| |
7. | Turn gas control knob counterclockwise | to “PILOT” |
| (see Figure 45). |
|
8. | Push in gas control knob all the way and hold. Immediately | |
| light the pilot by repeatedly depressing the piezo spark | |
| ignitor until a flame appears. Continue to hold for about | |
| one (1) minute after the pilot is lit. Release gas control knob | |
| and it will pop back. Pilot should remain lit. If it goes out, | |
| repeat steps 5 through 8. |
|
•If gas control knob does not pop up when released, stop and immediately call your service technician or gas supplier.
•If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your service technician or gas supplier.
9.Turn on all electric power to the fireplace.
10.Turn gas control knob counterclockwise to “ON”.
11. | This valve is equipped with a HI/LO feature. Set fireplace | ||||
| input as desired. |
|
|
| |
12. Close lower louver panel. | |||||
|
| Gas Control |
|
| Variable Control Knob |
|
|
|
|
| |
|
| Knob |
|
|
|
| Piezo |
| IL |
|
|
| Ignitor | O | OT | O | |
|
|
| P | IH | |
|
| F | F |
|
|
|
|
|
|
| N |
|
|
|
|
| LO |
Figure 45 - Control Valve |
|
|
| ||
|
| TO TURN OFF GAS | |||
|
| TO APPLIANCE | |||
1. | Open lower louver panel. |
MANUAL LIGHTING
PROCEDURE
1.Remove glass door (see Removing/Replacing Glass Door, page 21).
2.Follow steps 1 through 8 under Lighting Instructions, page 23.
3.Depress gas control knob and light pilot with match.
4. | Keep gas control knob pressed in for 30 seconds after light- |
| ing pilot. After 30 seconds, release gas control knob. Follow |
| steps 10 through 12 under Lighting Instructions. |
5.Replace glass door (see Removing/Replacing Glass Door, page 21).
OPTIONAL HAND-HELD
REMOTE OPERATION
Note: All remote control accessories must be purchased sepa- rately (see Accessories, page 36). Follow instructions included with the remote control.
NOTICE: You must light the pilot before using the
After lighting, let pilot flame burn for about one minute. Turn control knob to ON position. Adjust flame adjustment knob anywhere between HI and LO. Slide the selector switch to the REMOTE position (see Figure 46). Note: The burner may light if
IMPORTANT: Do not leave the selector switch in the REMOTE or ON position when the pilot is not lit. This will drain the battery.
2.Set selector switch in the OFF position to prevent draining battery.
3.Turn off all electrical power to the appliance if service is to be performed.
4.Push in gas control knob slightly and turn clockwise to “OFF”.
5.Close lower louver panel.
Shutting Off Burners Only (pilot stays lit) |
You may shut off the burners and keep the pilot lit by doing |
Blower Control Knob
(Optional Accessory)
OFF
ON
Selector Switch | ON OFF REMOTE | |
in Remote | ||
| ||
Position |
|
|
| Variable |
|
|
| Control Knob | |
N |
|
| |
O |
| L |
|
|
|
| |
T |
| O | I |
L |
| O | H |
O |
|
|
|
I | F |
| |
| P F |
| |
Gas Control Knob | |||
in ON Position |
|
one of the following: |
| |
1. | Turn gas control knob clockwise | to the PILOT position. |
2.Set selector switch in the OFF position.
Figure 46 - Setting the Selector Switch, Gas Control Knob and Variable Control Knob for Remote Operation
www.desatech.com |