16

VENTING INSTALLATION INSTRUCTIONS

Parts Lists for Venting Kits and Components (Cont.)

FIREPLACE INSTALLATION

Check Gas Type

Installing Optional Blower Accessory

VENTING INSTALLATION INSTRUCTIONS

Continued

PARTS LISTS FOR VENTING KITS AND COMPO- NENTS (CONT.)

Number Description

VR-58 Vertical Restrictor, Galvanized

S-58 Vinyl Siding Standoff, Galvanized WS-58 Wall Strap

CS-58 Cathedral Ceiling Support

FP-58 Firestop Plate

SF-58 Stucco Flashing - For use with HTS-5

FIREPLACE INSTALLATION

CHECK GAS TYPE

Use proper gas type for the fireplace unit you are installing. If your gas supply is not correct, do not install fireplace. See retailer where you purchased the fireplace for proper fireplace according to your gas type or to purchase gas conversion kit (see Accessories, page 37).

5.Mount speed control box to switch bracket by placing the plastic control shaft forward through the opening in the switch bracket (see Figure 26).

6.While supporting speed control, secure control shaft with lock nut by pushing and turning lock nut with pliers clockwise until it is tight against front panel. Place control knob provided on shaft.

7.Turn on power to duplex outlet if previously turned off per the warning in column 1, page 16.

8.Plug in blower power cord.

a.If your firebox is installed as a freestanding unit with an accessory mantel, determine whether the power cord will exit the left side or the right side of the firebox. Route power cord through exit hole and plug the power cord into a wall receptacle near the firebox.

b.If your firebox installation is recessed and/or pre-wired, plug the power cord into the duplex outlet provided. Refer to your firebox owner’s manual for instructions on wiring the duplex outlet.

CAUTION: Never touch the blower wheel while in operation.

INSTALLING OPTIONAL BLOWER

ACCESSORY

NOTICE: If installing blower in an existing fireplace with gas connections, shut off gas supply and dis- connect heater from gas supply. Contact a qualified service person to do this.

WARNING: If there is a duplex electrical outlet installed in the right side of the bottom of the fireplace base area, be sure that the electrical power to the outlet is turned off before proceeding with blower installation. Failure to do this may result in serious injury.

Model BK Installation

Follow all instructions provided in the blower accessory kit.

1.Attach the power cord to the blower motor by firmly pushing the two female terminals at the end of the power cord onto the two spade terminals on the blower motor (see Figure 25, page 17).

2.Attach green ground wire from power cord to blower hous- ing using screw provided (see Figure 25, page 17). Tighten screws securely.

3.Place the blower against the lower rear wall of the firebox outer wrapper with the exhaust port directed upward. The blower will fit inside the back opening and be held in position against the back wall by the magnets (see Figure 25, page 17).

4.Be certain that all wire terminals are securely attached to ter- minals on blower motor and that the screw retaining the green ground wire is tight.

Blower

Location

Lower Firebox

Cavity

Side View

Magnetic Strips

 

Spade Terminals

Exhaust

 

Port

Green

 

Ground Wire

Screw

Figure 25 - Blower Model BK

 

Switch

Speed Control

Bracket

Blower

 

 

Plug-In

Control

Knob

Locknut

Control

Duplex Outlet

 

Shaft

 

(Located underneath

 

 

 

 

firebox floor against

 

 

lower right outside wall)

Figure 26 - Attaching Speed Control to Firebox

For..com

111907-01D

Page 16
Image 16
Desa VV42ENB(1) Fireplace Installation, Check GAS Type, Installing Optional Blower Accessory, Model BK Installation

V42EN-A, VV42EPB(1), V42EP-A, VV42ENB(1) specifications

Desa VV42ENB(1), VV42EPB(1), V42EN-A, and V42EP-A are innovative products designed to enhance residential heating and hot water solutions. These units are a part of a modern era in energy-efficient home appliances that aim to provide comfort while minimizing environmental impact.

The VV42ENB(1) and VV42EPB(1) models are particularly notable for their energy efficiency. They incorporate advanced technology that significantly reduces energy consumption compared to traditional heating systems. The VV42ENB(1), which operates using natural gas, is designed for environments where gas is readily available, while the VV42EPB(1) utilizes propane, making it ideal for areas without natural gas supply. The flexibility in fuel sources provides homeowners with more options tailored to their specific needs.

Both models are equipped with a high-efficiency burner that optimizes fuel combustion, ensuring efficient heat transfer and reduced greenhouse gas emissions. The integrated smart thermostat feature allows users to program their heating schedules, which not only enhances comfort but also contributes to energy conservation by reducing wastage when the home is unoccupied.

Transitioning to the V42EN-A and V42EP-A models, these units are designed to cater to different heating requirements. Featuring advanced electronic ignition systems, they provide reliable operation with minimal maintenance requirements. The aesthetic design of these models allows them to blend seamlessly into any home decor while the durable materials ensure longevity and resilience under various conditions.

Furthermore, the V42EN-A and V42EP-A models come with enhanced safety features, including auto shut-off systems and flame failure devices that protect against unintended incidents. Homeowners can trust that these units will operate safely and efficiently.

In summary, the Desa VV42ENB(1), VV42EPB(1), V42EN-A, and V42EP-A are remarkable advancements in home heating technology. Their focus on energy efficiency, user-friendly features, and safety makes them a perfect choice for modern households looking to enhance comfort while maintaining a commitment to sustainability. With options for different fuels and advanced functionalities, they stand as a testament to innovation in the heating industry. These models promise not only to keep homes warm but also to do so in an environmentally responsible manner.