26

OPERATING FIREPLACE

Operating Optional Blower Accessory

INSPECTING BURNERS

Pilot Assembly

Burner Flame Pattern

OPERATING FIREPLACE

Continued

OPERATING OPTIONAL

BLOWER ACCESSORY

Locate the blower controls by opening the lower louver panel on the fireplace. Blower controls are located on the left side of the switch bracket to the left just inside the louver panel.

The BK manual blower and the BKT thermostatically-con- trolled blower have an ON setting and an OFF setting. The blower will only run when the switch is in the ON position. In the OFF position, the blower will not operate.

Note for BKT Only: If you are using BKT blower with optional thermostat (wall mounted or remote control) for the fireplace, your fireplace and blower will not turn on and off at the same time. The fireplace may run for several minutes before the blower turns on. After the heater modulates to the pilot position, the blower will continue to run. The blower will shut off after the firebox temperature decreases.

The blower helps distribute heated air from the fireplace. Periodically check the louvers of the firebox and remove any dust, dirt, or other obstructions that will hinder the flow of air.

INSPECTING BURNERS

Check pilot flame pattern and burner flame patterns often.

PILOT ASSEMBLY

The pilot assembly is factory preset for the proper flame. Alterations may have occurred during shipping and handling. The pilot is located on the back right hand side of the burner.

The flame must envelope 1/4" of top of the ignitor/sensor and grounding stem.

If your pilot assembly does not meet these requirements:

Turn the adjustment screw marked PILOT clockwise to decrease or counterclockwise to increase the flame to proper size (see Figure 49, page 25). Do not remove the adjustment screw.

see Troubleshooting, pages 28 and 29

Pilot Burner

Sensing Rod

 

 

Ignitor/Sensor

Figure 51 - Correct Pilot Flame Pattern

BURNER FLAME PATTERN

Burner flames will be steady; not lifting or floating. Flame patterns will be different from unit to unit and will vary depending on installation type and weather conditions.

If the vent configuration is installed incorrectly, the flames will lift or "ghost". This can be dangerous. Inspect the flames after installa- tion to ensure proper installation and performance.

Figure 52 shows a typical flame pattern.

If burner flame pattern differs from that described:

turn fireplace off (see To Turn Off Gas to Appliance, page 25)

see Troubleshooting, pages 28 and 29

Figure 52 - Typical Flame Pattern

For..com

111907-01D

Page 26
Image 26
Desa V42EN-A, VV42ENB(1) Inspecting Burners, Operating Optional Blower Accessory, Pilot Assembly, Burner Flame Pattern

V42EN-A, VV42EPB(1), V42EP-A, VV42ENB(1) specifications

Desa VV42ENB(1), VV42EPB(1), V42EN-A, and V42EP-A are innovative products designed to enhance residential heating and hot water solutions. These units are a part of a modern era in energy-efficient home appliances that aim to provide comfort while minimizing environmental impact.

The VV42ENB(1) and VV42EPB(1) models are particularly notable for their energy efficiency. They incorporate advanced technology that significantly reduces energy consumption compared to traditional heating systems. The VV42ENB(1), which operates using natural gas, is designed for environments where gas is readily available, while the VV42EPB(1) utilizes propane, making it ideal for areas without natural gas supply. The flexibility in fuel sources provides homeowners with more options tailored to their specific needs.

Both models are equipped with a high-efficiency burner that optimizes fuel combustion, ensuring efficient heat transfer and reduced greenhouse gas emissions. The integrated smart thermostat feature allows users to program their heating schedules, which not only enhances comfort but also contributes to energy conservation by reducing wastage when the home is unoccupied.

Transitioning to the V42EN-A and V42EP-A models, these units are designed to cater to different heating requirements. Featuring advanced electronic ignition systems, they provide reliable operation with minimal maintenance requirements. The aesthetic design of these models allows them to blend seamlessly into any home decor while the durable materials ensure longevity and resilience under various conditions.

Furthermore, the V42EN-A and V42EP-A models come with enhanced safety features, including auto shut-off systems and flame failure devices that protect against unintended incidents. Homeowners can trust that these units will operate safely and efficiently.

In summary, the Desa VV42ENB(1), VV42EPB(1), V42EN-A, and V42EP-A are remarkable advancements in home heating technology. Their focus on energy efficiency, user-friendly features, and safety makes them a perfect choice for modern households looking to enhance comfort while maintaining a commitment to sustainability. With options for different fuels and advanced functionalities, they stand as a testament to innovation in the heating industry. These models promise not only to keep homes warm but also to do so in an environmentally responsible manner.