FIREPLACE INSTALLATION

Installing Gas Piping to Fireplace Location (Cont.) Connecting Fireplace To Gas Supply

19

FIREPLACE INSTALLATION

Continued

We recommend that you install a sediment trap/drip leg in supply line as shown in Figure 31. Locate sediment trap/drip leg where it is within reach for cleaning. Install in piping system between fuel supply and fireplace. Locate sediment trap/drip leg where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into fireplace gas con- trols. If sediment trap/drip leg is not installed or is installed wrong, fireplace may not run properly.

CSA Design-Certified

Manual background Equipment Shutoff Valve

with 1/8" NPT Tap*

CONNECTING FIREPLACE TO GAS SUPPLY

Installation Items Needed

5/16" hex socket wrench or nut-driver

sealant (resistant to propane/LP gas, not provided)

1.

Open lower louver door panel by gently pulling forward.

2.

Route flexible gas line (provided by installer) from equipment

 

shutoff valve to fireplace. Route flexible gas supply line through

 

one of the access holes on side of fireplace.

3.

Attach flexible gas line from gas supply to control valve (see

Approved Flexible

Gas Line

3" Minimum Manual background

Natural - From Gas Meter (5.5" W.C. to 10.5"

W.C. Pressure)

Propane/LP From External Regulator (11" W.C. to 14" W.C. Pressure)

Figure 32).

4. Check all gas connections for leaks. See Checking Gas Con-

nections, page 20.

 

Red Surface Indicates

Equipment

For Propane/LP Use Only

Flexible Gas Line

Shutoff Valve

Do NOT Kink

Cap Pipe Nipple Tee Joint

1/2" NPT Incoming

 

 

Gas Line

Inlet Pressure Tap

Outlet Pressure Tap

 

Figure 31 - Gas Connection

Sediment Trap/Drip Leg

Note: Wire Connections Not Shown for Clarity

*The CSA design-certified equipment shutoff valve may be sup- plied with the appliance or you can purchase it from your retailer.

Figure 32 - Connecting Flexible Gas Line to Electronic Valve