OPERATING FIREPLACE

For Your Safety Read Before Lighting

Lighting Instructions

To Turn Off Gas To Appliance

Manual Lighting Procedure

25

OPERATING FIREPLACE

FOR YOUR SAFETY READ

BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing prop- erty damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING

INSTRUCTIONS

1.STOP! Read the safety information above.

2.Open lower louver panel.

3.Disconnect the wire that runs from TH to TPTH from the control valve.

4.Turn off all electric power to the fireplace.

5.Push in gas control knob slightly and turn clockwise to “OFF”.

6.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information above. If you don't smell gas, go to the next step.

7.The pilot is located by the main burner and should not re- quire accessing for lighting.

8.Turn gas control knob counterclockwise to “PILOT”.

9.Push in gas control knob all the way and hold. Immedi- ately light the pilot by repeatedly depressing the piezo spark ignitor until a flame appears. Continue to hold for about one (1) minute after the pilot is lit. Release gas control knob and it will pop back. Pilot should remain lit. If it goes out, repeat steps 5 through 8.

If gas control knob does not pop up when released, stop and immediately call your service technician or gas supplier.

If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your service technician or gas supplier.

10.Reconnect the wire that runs from TH to TPTH to the control valve.

11.Turn on all electric power to the fireplace.

12.Turn gas control knob counterclockwise to “ON”.

13.This valve is equipped with a HI/LO feature. Set fireplace input as desired.

14.Close lower louver panel.

 

Gas Control

Variable Control Knob

 

 

 

Knob

 

Piezo

 

 

Ignitor

ILOT

IH

O

O

 

P

 

F

N

 

F

 

 

 

 

LO

Figure 51 - Control Valve

TO TURN OFF GAS

TO APPLIANCE

1.Open lower louver panel.

2.Set selector switch in the OFF position to prevent draining battery.

3.Turn off all electrical power to the appliance if service is to be performed.

4.Push in gas control knob slightly and turn clockwise to “OFF”.

5.Close lower louver panel.

Shutting Off Burners Only (pilot stays lit)

You may shut off the burners and keep the pilot lit by doing one of the following:

1. Turn gas control knob clockwise to the PILOT position.

2.Set selector switch in the OFF position.

MANUAL LIGHTING

PROCEDURE

1.Remove glass door (see Removing/Replacing Glass Door, page 22.)

2.Follow steps 1 through 8 under Lighting Instructions.

3.Depress gas control knob and light pilot with match.

4.Keep gas control knob pressed in for 30 seconds after light- ing pilot. After 30 seconds, release gas control knob. Fol- low steps 10 through 14 under Lighting Instructions.

5.Replace glass door (see Removing/Replacing Glass Door,

page 22).

For morevisit www..com

108661-01E

Page 25
Image 25
Desa (V)VC36N Series installation manual Operating Fireplace, For Your Safety Read Before Lighting, Lighting Instructions

(V)VC36N Series specifications

The Desa (V)VC36N Series is a versatile and sophisticated line of heating solutions designed to provide optimal comfort and energy efficiency. This series is engineered with cutting-edge technology, offering a range of features that cater to diverse heating needs, making it an ideal choice for residential and commercial applications.

One of the standout features of the VC36N Series is its impressive heating capacity. With a robust output, these units can effectively warm large spaces, ensuring a cozy environment during the colder months. The efficient heat distribution system optimizes warmth throughout the area, eliminating cold spots and enhancing overall comfort.

Additionally, the VC36N Series incorporates advanced burner technology, which not only contributes to its efficiency but also minimizes emissions. This eco-friendly design helps in reducing the carbon footprint, making it a responsible choice for environmentally conscious consumers. The burners are also engineered for longevity, ensuring reduced maintenance needs over the lifespan of the unit.

Another significant characteristic of the VC36N Series is its user-friendly controls. The intuitive interface allows for easy adjustments of temperature and settings, making it accessible for users of all experience levels. Some models even support remote access, enabling users to manage heating preferences from their smartphones or tablets, thereby enhancing convenience.

Moreover, the design of the VC36N Series emphasizes durability and aesthetic appeal. Constructed with high-quality materials, these units are built to withstand the rigors of daily use while maintaining a sleek and modern look that complements various interior styles.

Safety features are also paramount in the VC36N Series, with integrated systems designed to ensure safe operation. These include flame sensing technology and automatic shut-off mechanisms, providing peace of mind for users.

In summary, the Desa (V)VC36N Series stands out as a premium choice in heating solutions. With its powerful performance, energy-efficient technologies, user-friendly features, durable construction, and robust safety measures, it exemplifies quality and reliability, making it suitable for a wide range of applications. Whether for home use or in commercial settings, the VC36N Series is engineered to meet the demands of modern heating while prioritizing environmental sustainability and user comfort.