Minimum clearances to combustibles for the fireplace are as follows:

Back, and sides 0"/mm

Perpendicular walls 6" (152mm)

Floor 0"/mm

Ceiling to louver opening 42" (1067mm)

Front 36" (914mm)

Top 0"/mm

Vent (See venting instructions for

specific venting clearances.)

Combustible material with a maximum thickness of 5/8" may be

flush with the top front of fireplace .

FRAMING AND FINISHING

Figure 4 shows typical framing of this fireplace. Figure 5 shows

framing for corner installation. All minimum clearances must be met.

For available accessories for this fireplace, see Accessories on page

37. If you are using a separate combustible mantel piece, refer to

Figure 6 for proper installation height. You can install noncombus-

tible mantels at any height above the fireplace.

Note:

Noncombus-

tible mantels may discolor!

PRE-INSTALLATIONPREPARATION
Continued

NOTICE: This fireplace is intended for use as supple-

mental heat. Use this fireplace along with your pri-

mary heating system. Do not install this fireplace as

your primary heat source. If you have a central heat-

ing system, you may run systems circulating blower

while using fireplace. This will help circulate the heat

throughout the house. In the event of a power outage,

you can use this fireplace as a heat source.

Figure 4 - Framing Clearances for Installation Against an Exterior
Wall
32" Models 36" Models
A32
3/8"36
1/8"
B34
5/8"41
1/4"
C 19" 231/2"
C
B
A
DE
FG
Top of Louver Opening
3
2
1
4
5
6
7
Wall
A
B
E
F
G
H
DC
Nailing Tabs
Figure 5 - Framing Clearances for Corner Installation
Ref. Mantel Depth Ref. Mantel from Top
of Louver Opening
1 14" (356mm) A 16" (406mm)
2 12" (305mm) B 14" (356mm)
3 10" (254mm) C 12" (305mm)
4 8" (203mm) D 10" (254mm)
5 6" (152mm) E 8" (203mm)
6 4" (101mm) F 6" (152mm)
7 2" (51mm) G 4" (101mm)
32" Models 36" Models
A28
1/2"35
3/4"
B13
5/8" 15"
C39
3/8"49
5/8"
D9
1/2"10
3/8"
E9
7/8"13
3/4"
F34
3/8" 41"
G34
5/8"41
1/4"
H54
1/8"68
1/2"
Figure 6 - Clearances for Combustible Mantels
PRE-INSTALLATION PREPARATION
Clearances
Framing and Finishing