8

VENTING INSTALLATION INSTRUCTIONS

Installation Planning

VENTING INSTALLATION INSTRUCTIONS

Continued

2.Direct vent pipe sections and components are designed with special twist-lock connections.

Twist-Lock Procedure: The female ends of the pipes have locking lugs (indentations). These lugs will slide straight into matching slots on the male ends of adjacent pipes. Push pipe sections together and twist one section clockwise approximately one-quarter turn until the sections are fully locked (see Figure 8). Note: Horizontal runs of vent must be supported every three feet. Use wall straps for this purpose.

3.Use a 45° elbow to connect venting system to fireplace flue col- lar. The elbow is designed to be twist-locked onto the flue collar as described in step 2. IMPORTANT: Do not attempt to alter the configuration of the elbow by cutting, twisting, bending, etc.

4.Assemble the desired combination of pipe and elbows to the fireplace. If there are long portions of venting run, pre-as- sembled pipe sections may be installed as subassemblies for convenience.

5.Carefully determine the location where the vent pipe assembly will penetrate the outside wall. The center of the hole should line up with the center-line of the horizontal vent pipe. Mark the wall for a 10" x 10" square hole. Cut and frame the square hole in the exterior wall where the vent will be terminated. If the wall being penetrated is constructed of noncombustible material, such as masonry block or concrete, a 7 3/4" hole with zero clearance is acceptable (see Figure 9).

WARNING: Do not recess vent termination into any wall. This will cause a fire hazard.

6.Noncombustible Exterior Wall: Position the horizontal vent cap in the center of the 7 3/4" round hole and attach to the exte- rior wall with four wood screws provided. Before attaching the vent cap to exterior wall, run a bead of non-hardening mastic (pliable sealant) around the outside edges to make a seal be- tween it and the outside wall. Note: The four wood screws provided should be replaced with appropriate fasteners for stucco, brick, concrete, or other types of sidings.

Male

Slots

Female

Locking

Lugs

Figure 8 - Vent Pipe Connections

Vent Opening

 

 

Combustible Wall

10" Inside Framing

 

 

10"

 

(254mm)

(254mm)

 

 

10"

 

 

(254mm)

 

 

 

(Framing

Vent Opening

 

Detail)

 

 

Noncombustible Wall

 

 

7 3/4"

 

 

(197mm)

 

 

 

 

Center

 

 

of Hole

Figure 9 - Vent Opening Requirements

For..com

108661-01E

Page 8
Image 8
Desa (V)VC36N Series installation manual Vent Pipe Connections

(V)VC36N Series specifications

The Desa (V)VC36N Series is a versatile and sophisticated line of heating solutions designed to provide optimal comfort and energy efficiency. This series is engineered with cutting-edge technology, offering a range of features that cater to diverse heating needs, making it an ideal choice for residential and commercial applications.

One of the standout features of the VC36N Series is its impressive heating capacity. With a robust output, these units can effectively warm large spaces, ensuring a cozy environment during the colder months. The efficient heat distribution system optimizes warmth throughout the area, eliminating cold spots and enhancing overall comfort.

Additionally, the VC36N Series incorporates advanced burner technology, which not only contributes to its efficiency but also minimizes emissions. This eco-friendly design helps in reducing the carbon footprint, making it a responsible choice for environmentally conscious consumers. The burners are also engineered for longevity, ensuring reduced maintenance needs over the lifespan of the unit.

Another significant characteristic of the VC36N Series is its user-friendly controls. The intuitive interface allows for easy adjustments of temperature and settings, making it accessible for users of all experience levels. Some models even support remote access, enabling users to manage heating preferences from their smartphones or tablets, thereby enhancing convenience.

Moreover, the design of the VC36N Series emphasizes durability and aesthetic appeal. Constructed with high-quality materials, these units are built to withstand the rigors of daily use while maintaining a sleek and modern look that complements various interior styles.

Safety features are also paramount in the VC36N Series, with integrated systems designed to ensure safe operation. These include flame sensing technology and automatic shut-off mechanisms, providing peace of mind for users.

In summary, the Desa (V)VC36N Series stands out as a premium choice in heating solutions. With its powerful performance, energy-efficient technologies, user-friendly features, durable construction, and robust safety measures, it exemplifies quality and reliability, making it suitable for a wide range of applications. Whether for home use or in commercial settings, the VC36N Series is engineered to meet the demands of modern heating while prioritizing environmental sustainability and user comfort.