TROUBLESHOOTING

27

TROUBLESHOOTING

Continued

WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

 

Fireplace produces a clicking/ticking noise

1.

Metal expanding while heating or con-

1.

This is common with most fireplaces.

just after burner is lit or shut off

 

tracting while cooling

 

If noise is excessive, contact qualified

 

 

 

 

service person

 

 

 

 

 

Slight smoke or odor during initial

1.

Residues from manufacturing processes

1.

Problem will stop after a few hours of

operation

 

and logs curing

 

operation

 

 

 

 

 

Gas odor even when control knob is in OFF

1.

Gas leak. See Warning statement at

1.

Locate and correct all leaks (see Check-

position

 

top of page

 

ing Gas Connections, page 19)

 

2.

Control valve defective

2.

Replace control valve

 

 

 

 

 

Gas odor during combustion

1.

Foreign matter between control valve

1.

Take apart gas tubing and remove for-

 

 

and burner

 

eign matter

 

2.

Gas leak. See Warning statement at

2.

Locate and correct all leaks (see Check-

 

 

top of page

 

ing Gas Connections, page 19)

 

 

 

 

 

Glass soots

1.

Debris around burner air mixer

1.

Inspect the opening at the base of the

 

 

 

 

burner by removing log/grate assem-

 

 

 

 

bly to see that it is NOT packed with

 

 

 

 

any type of material [see Installing

 

 

 

 

Brick Liner Models BL36DA(SA) and

 

 

 

 

BL36DHA(SA)] for log/grate removal

 

2.

Improper vent configureation

2.

Check vent configuration specifications

 

 

 

 

(see Venting Installation Instructions,

 

 

 

 

page 7)

 

 

 

 

 

Dark residue on logs or inside of fireplace

1.

Air holes at burner inlet blocked

1.

Clean out air holes at burner inlets. Pe-

 

 

 

 

riodically repeat as needed

 

2.

Burner flame holes blocked

2.

Remove blockage

 

3.

Improper venting or excessive blockage

3.

Have the vent system inspected, includ-

 

 

 

 

ing the termination cap. Remove any

 

 

 

 

restrictions or obstruction

 

4.

Excessive amounts of embers and pan

4.

Clear excess embers until a minimum

 

 

material

 

gap of 1/2" remains under the grate

116235-01C

www.desatech.com

Page 27
Image 27
Desa (V)VC36PE, (V)VC36NE installation manual Gas leak. See Warning statement at

(V)VC36NE, (V)VC36PE specifications

Desa (V)VC36NE and (V)VC36PE are advanced probe technology designed for precise diagnostic and measurement applications in various industries, including manufacturing, automotive, and healthcare. These models are representative of Desa's commitment to innovation and excellence in engineering, providing users with essential features and cutting-edge technologies.

One of the main features of the (V)VC36NE model is its enhanced resolution, allowing for accurate data collection even in the most challenging environments. This high-resolution capability makes it ideal for detailed inspections and quality control, ensuring that manufacturers can meet stringent performance standards. Meanwhile, the (V)VC36PE model is equipped with a user-friendly interface that simplifies data interpretation, making it accessible to operators with varying levels of technical expertise.

Both models utilize advanced sensing technologies, including capacitive and resistive sensing, enabling them to capture real-time data with exceptional precision. This technology effectively reduces the margin for error, which is critical in applications where even minor discrepancies can lead to significant consequences. Furthermore, the integration of wireless communication in these models allows for seamless data transmission, enhancing connectivity and facilitating remote monitoring capabilities.

Another characteristic that sets Desa's (V)VC36NE and (V)VC36PE apart is their durability. Constructed with high-grade materials, they are designed to withstand harsh operating conditions, ensuring longevity and reliability. This robustness means that users can depend on these probes for consistent performance over time, reducing downtime and maintenance costs.

The versatility of the (V)VC36NE and (V)VC36PE models is another notable advantage. They are compatible with a broad range of accessories and can be easily integrated into existing systems, making them suitable for various applications across different sectors. Whether for industrial automation or healthcare diagnostics, these models provide excellent adaptability.

In conclusion, Desa’s (V)VC36NE and (V)VC36PE probes exemplify the brand's focus on delivering high-performance, reliable, and user-centric diagnostic solutions. Their advanced features, including high resolution, durable construction, and versatile compatibility, make them invaluable tools in modern industries, enhancing productivity and efficiency while ensuring high-quality outcomes.