Desa (V)VC42P SERIES Venting Installation, Instructions, Fireplace Installation, Check Gas Type

Models: (V)VC42P SERIES (V)VC42N SERIES

1 40
Download 40 pages 42.29 Kb
Page 16
Image 16
VENTING INSTALLATION

16

VENTING INSTALLATION INSTRUCTIONS Parts List for Venting Kits and Components FIREPLACE INSTALLATION Check Gas Type Installing Optional Blower Accessories

VENTING INSTALLATION

INSTRUCTIONS

Continued

PARTS LIST FOR VENTING KITS AND

COMPONENTS

DESA (5"/8") Pipe & Vent Kits

Number

Description

P58-6

6" Section Double Wall Pipe, Galvanized

P58-12

12" Section Double Wall Pipe, Galvanized

P58-24

24" Section Double Wall Pipe, Galvanized

P58-36

36" Section Double Wall Pipe, Galvanized

P58-48

48" Section Double Wall Pipe, Galvanized

PA58-712

Adjustable 7"-12" Section Double Wall Pipe,

 

Galvanized

E58-45

45° Elbow, Galvanized

E58-90

90° Elbow, Galvanized

VKG-58

Ground Floor Vent Kit, Galvanized (Includes: 45° El-

 

bow, 7"-12" Adjustable Pipe, Wall Firestop, Horizontal

 

Square Termination, 16 Screws)

VKB-58

Basement Vent Kit, Galvanized (Includes: 45° Elbow,

 

7"-12" Adjustable Pipe, Wall Firestop, Horizontal

 

Square Termination, 4' Pipe, 90° Elbow, 20 Screws)

VKS-58

Snorkel Vent Kit, Galvanized (Includes: 45° Elbow,

 

7"-12" Adjustable Pipe, Wall Firestop, 36" Snorkel

 

Termination, 4' Pipe, 1' Pipe, 90° Elbow, 26 Screws)

VKR-58

Roof Vent Kit, Galvanized (Includes: 45° Elbow, 7"-12"

 

Adjustable Pipe, Flue Restrictor, Vertical High Wind

 

Termination, 2' Pipe, 4' Pipe, Wall Firestop, Storm

 

Collar, Roof Flashing [0/12 - 6/12], 26 Screws)

VKC-58

Corner Vent Kit, Galvanized (Includes 45° Elbow,

 

7"-12" Adjustable Pipe, Wall Firestop, Horizontal

 

Termination, 6" Pipe, 90° Elbow, 18 Screws)

HTK-58

Horizontal Round Termination Kit (Includes Round

 

Termination, Wall Firestop, 45° Elbow)

HT-58

Horizontal Round Termination, Galvanized

HTS-58

Horizontal Square Termination, Galvanized

HTKS-58

Horizontal Square Termination Kit (Includes: Square

 

Termination, Wall Firestop, 45° Elbow)

VT-58

Vertical Round Termination, Galvanized

ST-58-14

14" Snorkel Termination, Galvanized

ST-58-36

36" Snorkel Termination, Galvanized

SC-58

Storm Collar, Galvanized

WF-58

Wall Firestop, Galvanized

RF-58-6

Roof Flashing - 0 to 6/12 Pitch, Galvanized

RF-58-12

Roof Flashing - 6/12 to 12/12 Pitch, Galvanized

VR-58

Vertical Restrictor, Galvanized

S-58

Vinyl Siding Standoff, Galvanized

WS-58

Wall Strap

CS-58

Cathedral Ceiling Support

FP-58

Firestop Plate

SF-58

Stucco Flashing - For use with HTS-58

FIREPLACE INSTALLATION

.CHECK GAS TYPE

Use proper gas type for the fireplace unit you are installing. If you have conflicting gas types, do not install fireplace. See retailer where you purchased the fireplace for proper fireplace according to your gas type or to purchase gas conversion kit (see Accessories, page 36).

INSTALLING OPTIONAL BLOWER

ACCESSORIES

NOTICE: If installing blower in an existing fireplace with gas connections, shut off gas supply and dis- connect heater from gas supply. Contact a qualified service person to do this.

INSTRUCTIONS WARNING: If there is a duplex electrical outlet installed in the right side of the bottom of the fireplace base area, be sure that the electrical power to the outlet is turned off before proceeding with blower installation. Failure to do this may result in serious injury.

Model BK Installation

Follow all instructions provided in the blower accessory kit.

1.Attach the power cord to the blower motor by firmly pushing the two female terminals at the end of the power cord onto the two spade terminals on the blower motor (see Figure 25).

2.Attach green ground wire from power cord to blower hous- ing using screw provided (see Figure 25). Tighten screws securely.

3.Place the blower against the lower rear wall of the firebox outer wrapper with the exhaust port directed upward. The blower will fit inside the back opening and be held in position against the back wall by the magnets (see Figure 25).

4.Be certain that all wire terminals are securely attached to ter- minals on blower motor and that the screw retaining the green ground wire is tight.

 

Blower

 

Location

Lower Firebox

 

Cavity

 

Side View

 

Spade Terminals

Magnetic

Strips

 

Green Ground Wire

Screw

 

 

Exhaust Port

Figure 25 - Blower Model BK

 

www.desatech.com

116236-01B

Page 16
Image 16
Desa (V)VC42P SERIES Venting Installation, Instructions, Fireplace Installation, Check Gas Type, Components, Continued