4

PRODUCT FEATURES PRE-INSTALLATION PREPARATION

Location and Space Requirements

PRODUCT FEATURES

These are a few facts that can help you understand and enjoy your direct-vent fireplace:

The venting system may be routed to the outside of your home in several ways. It may vent through the roof (vertical) or it may vent to an outside/exterior wall (horizontal). The vent pipe instal- lation is very important to allow for proper operation. You must follow the venting instructions very carefully for either vertical or horizontal applications.

This fireplace may be installed in any room of your house provided all local codes and these installation instructions are followed.

The blower requires electricity. If you plan to install the blower at a later date, do not forget to wire the outlet at the bottom of the fireplace when framing.

Each time you turn on your fireplace, you may notice some amount of condensation on the inside of the fireplace glass. This is normal and will disappear after 10-20 minutes of operation.

Your direct-vent gas fireplace system (fireplace and venting) is a balanced and sealed gas operating unit. It requires approximately 10- 20 minutes of operating time before the flame pattern stabilizes.

If you plan on installing a television or entertainment center re- cessed above your fireplace, it is recommended that you maintain a minimum 18" above top of louver opening.

When locating termination cap, it is important to observe the minimum clearances shown in Figure 7, page 6.

If recessing into a wall, you can avoid extra framing by position- ing your fireplace against an already existing framing member.

Do not recess termination cap into a wall or siding.

You may paint the termination cap with 450ºF (232ºC) heat- resistant paint to coordinate with the exterior finish.

There must not be any obstruction such as bushes, garden sheds, fences, decks or utility buildings within 24" from the front of the termination cap.

Do not locate termination cap where excessive snow or ice build up may occur. Be sure to clear vent termination area after snow falls to prevent accidental blockage of venting system. When using snow blowers, do not direct snow towards vent termination area.

PRE-INSTALLATION

PREPARATION

LOCATION AND SPACE REQUIREMENTS

Determine the safest and most efficient location for your DESA direct-vent fireplace. Make sure that rafters and wall studs are not in the way of the venting system. Choose a location where the heat output is not affected by drafts, air conditioning ducts, windows or doors. Figure 2 shows some common locations. Be aware of all restrictions and precautions before deciding the exact location for your fireplace and termination cap.

When deciding the location of your fireplace, follow these rules:

Do not connect this fireplace venting to a chimney flue serving a separate solid-fuel burning fireplace or appliance.

Due to high temperatures, do not locate this fireplace in high traf- fic areas, windy or drafty areas or near furniture or draperies.

Proper clearances must be maintained.

If your fireplace is to be installed directly on carpeting, vinyl tile or any combustible material other than wood, it must be installed on a metal or wood panel extending the full width and depth of the fireplace. See Figure 3.

Your fireplace is designed to be used in zero clearance instal- lations. Wall or framing material can be placed directly against any exterior surface on the back, sides or top of your fireplace, except where standoff spacers are integrally attached. If standoff spacers are attached to your fireplace, these spacers can be placed directly against wall or framing material. See framing details on page 5.

Flush with a wall

Through exterior wall enclosed in a chase

Figure 2 - Common Fireplace Locations

36 1/4"

23 1/4"

48"

Figure 3 - Fireplace Bottom Dimensions

Corner installation

www.desatech.com

116237-01A

Page 4
Image 4
Desa (V)VC42PE, (V)VC42NE Product Features, PRE-INSTALLATION Preparation, Location and Space Requirements

(V)VC42PE, (V)VC42NE specifications

Desa (V)VC42NE and (V)VC42PE are innovative heating solutions that cater to modern residential and commercial spaces. These advanced units embody a combination of efficiency, sustainability, and user-friendly features, making them highly sought after in the market.

The (V)VC42NE model stands out for its high energy efficiency, designed to provide optimal heating performance while minimizing energy consumption. This unit incorporates state-of-the-art condensing technology, which allows it to extract additional heat from exhaust gases, enhancing its overall energy efficiency. With a commendable seasonal efficiency rating, it is suitable for environments where reduced carbon footprints are a priority.

On the other hand, the (V)VC42PE model is engineered to offer unparalleled versatility. It supports a range of fuel options, including natural gas and propane, making it adaptable to various installations. This flexibility is particularly beneficial for users who may want to switch fuel sources in the future. The (V)VC42PE also includes a powerful fan system, which ensures even heat distribution throughout the space, eliminating cold spots.

Both models are equipped with advanced safety features that comply with stringent industry standards. These include flame failure devices, pressure relief valves, and overheat protection systems that ensure the units operate safely under all conditions. Additionally, they are designed for low maintenance, with accessible components that simplify servicing and repairs.

One of the standout characteristics of both Desa models is their intuitive control systems. The units feature digital thermostats that allow users to set and monitor temperatures effortlessly. Moreover, they offer programmable settings that enable users to optimize heating schedules according to their lifestyle needs. This feature contributes to enhanced comfort while further promoting energy savings.

In terms of design, both the (V)VC42NE and (V)VC42PE models possess a sleek, modern aesthetic that integrates seamlessly into various interior styles. Their compact size allows for easy installation in tight spaces, making them an ideal choice for apartments, offices, and other limited areas.

In summary, Desa (V)VC42NE and (V)VC42PE units are exemplary heating systems that combine efficiency, safety, and user-friendly features, making them suitable for a wide range of applications. With their advanced technologies and commitment to sustainability, these models are poised to meet the demands of today's energy-conscious consumers.