CLEANING AND MAINTENANCE

Cleaning Burner Injector Holder and Pilot Air Inlet Hole Cabinet

19

CLEANING AND MAINTENANCE

WARNING: Turn off fireplace and let cool before cleaning.

CAUTION: You must keep control areas, burner, and circulating air passageways of fireplace clean. Inspect these areas of fireplace before each use. Have fireplace inspected yearly by a qualified service person. Fireplace may need more frequent cleaning due to excessive lint from carpeting, bedding mate- rial, pet hair, etc.

WARNING: Failure to keep the primary air opening(s) of the burner(s) clean may result in soot- ing and property damage.

CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE

The primary air inlet holes allow the proper amount of air to mix with the gas. This provides a clean burning flame. Keep these holes clear of dust, dirt, lint, and pet hair. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We recommend that you clean the unit every three months during operation and have heater inspected yearly by a qualified service person.

We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSI. Your local computer store, hardware store, or home center may carry com- pressed air in a can. You can use a vacuum cleaner in the blow position. If using compressed air in a can, please follow the direc- tions on the can. If you don't follow directions on the can, you could damage the pilot assembly.

1.Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes.

2.Inspect burner, pilot, and primary air inlet holes on injector holder for dust and dirt (see Figure 36).

3.Blow air through the ports/slots and holes in the burner.

4.Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint, or pet hair with a soft cloth or vacuum cleaner nozzle.

5.Blow air into the primary air holes on the injector holder.

6.In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4.

Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 37). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

Ports/Slots

Injector Holder

Burner Tube

Primary Air Inlet Holes

Figure 36 - Injector Holder On Outlet Burner Tube

Pilot Assembly

Pilot Air Inlet Hole

Figure 37 - Pilot Inlet Air Hole (Propane/LP Shown)

CABINET

Air Passageways

• Use a vacuum cleaner or pressurized air to clean.

Exterior

Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabinet to remove dust.

For morevisit www..com

111044-01D

Page 19
Image 19
Desa Tech CGCFTN Cleaning and Maintenance, Cleaning Burner Injector Holder and Pilot AIR Inlet Hole, Cabinet, Exterior

CGCFTP, CGCFTN specifications

Desa Tech, an innovator in the field of electronic components, has introduced the CGCFTN and CGCFTP series, designed to meet the varying needs of modern technology applications. These devices are engineered with high-performance features that make them suitable for a wide range of industries, including telecommunications, automotive, and consumer electronics.

One of the standout features of the CGCFTN and CGCFTP series is their impressive frequency range. These components are capable of operating within a broad spectrum, providing users with flexibility and ensuring that they can be leveraged in various high-frequency applications. The advanced design minimizes signal loss and maximizes efficiency, making them ideal for both analog and digital signal processing.

In terms of technology, the CGCFTN and CGCFTP series utilizes cutting-edge semiconductor technology, ensuring high speed and reliability. The components are manufactured using a robust fabrication process that adheres to international quality standards, resulting in devices that not only perform well but also boast long lifespans. The advanced materials used in their construction contribute to their strength, heat resistance, and overall durability.

The CGCFTP variant is particularly notable for its enhanced power handling capabilities, which ensures that it can efficiently manage high power levels without compromising performance. This makes it a valuable asset in high-demand environments, such as telecommunications infrastructure and industrial machinery.

Another characteristic of these components is their compact design, which allows for easy integration into various devices. This small footprint does not sacrifice performance, ensuring that users can achieve their design goals without needing to make substantial compromises on space or weight. Furthermore, both series feature low power consumption, making them environmentally friendly options for modern electronic designs.

Overall, the Desa Tech CGCFTN and CGCFTP series represents a significant advancement in electronic component technology. With features such as wide frequency range, high power handling, and reliable performance, they are well-suited for a multitude of applications. These devices exemplify Desa Tech’s commitment to innovation, quality, and sustainability, making them a preferred choice for engineers and manufacturers in various sectors striving for excellence in their designs.