TROUBLESHOOTING

TROUBLESHOOTING

Continued

WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating fireplace where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Fireplace produces a clicking/ticking noise just after burner is lit or shut off

1.Metal expanding while heating or con- tracting while cooling

1.This is common with most fireplaces. If noise is excessive, contact qualified ser- vice person

Fireplace produces unwanted odors

1.

Fireplace burning vapors from paint, hair

 

 

spray, glues, etc. (see IMPORTANT

 

 

statement above)

 

2.

Low fuel supply

 

3.

Gas leak. See Warning statement at

 

 

top of page

1.Ventilate room. Stop using odor caus- ing products while fireplace is running

2.Refill supply tank

3.Locate and correct all leaks (see Check- ing Gas Connections, page 16)

Fireplace shuts off in use (ODS operates)

1.

Not enough fresh air is available

1.

Open window and/or door for ventilation

 

2.

Low line pressure

2.

Contact local propane/LP or natural gas

 

 

 

 

company

 

3.

ODS/pilot is partially clogged

3.

Clean ODS/pilot (see Cleaning and

 

 

 

 

Maintenance, page 16)

 

 

 

 

 

Gas odor even when control knob is in OFF

1.

Gas leak. See Warning statement at

1.

Locate and correct all leaks (see Check-

position

 

top of page

 

ing Gas Connections, page 16)

 

2.

Control valve defective

2.

Replace control valve

Gas odor during combustion

1.

Foreign matter between control valve

 

 

and burner

 

2.

Gas leak. See Warning statement at

 

 

top of page

1.Take apart gas tubing and remove for- eign matter

2.Locate and correct all leaks (see Check- ing Gas Connections, page 16)

Moisture/condensation noticed on windows 1. Not enough combustion/ventilation air

1. Refer to Air for Combustion and Venti-

 

lation requirements (page 5)

For..com

111044-01D

Page 22
Image 22
Desa Tech CGCFTP, CGCFTN installation manual Gas leak. See Warning statement at

CGCFTP, CGCFTN specifications

Desa Tech, an innovator in the field of electronic components, has introduced the CGCFTN and CGCFTP series, designed to meet the varying needs of modern technology applications. These devices are engineered with high-performance features that make them suitable for a wide range of industries, including telecommunications, automotive, and consumer electronics.

One of the standout features of the CGCFTN and CGCFTP series is their impressive frequency range. These components are capable of operating within a broad spectrum, providing users with flexibility and ensuring that they can be leveraged in various high-frequency applications. The advanced design minimizes signal loss and maximizes efficiency, making them ideal for both analog and digital signal processing.

In terms of technology, the CGCFTN and CGCFTP series utilizes cutting-edge semiconductor technology, ensuring high speed and reliability. The components are manufactured using a robust fabrication process that adheres to international quality standards, resulting in devices that not only perform well but also boast long lifespans. The advanced materials used in their construction contribute to their strength, heat resistance, and overall durability.

The CGCFTP variant is particularly notable for its enhanced power handling capabilities, which ensures that it can efficiently manage high power levels without compromising performance. This makes it a valuable asset in high-demand environments, such as telecommunications infrastructure and industrial machinery.

Another characteristic of these components is their compact design, which allows for easy integration into various devices. This small footprint does not sacrifice performance, ensuring that users can achieve their design goals without needing to make substantial compromises on space or weight. Furthermore, both series feature low power consumption, making them environmentally friendly options for modern electronic designs.

Overall, the Desa Tech CGCFTN and CGCFTP series represents a significant advancement in electronic component technology. With features such as wide frequency range, high power handling, and reliable performance, they are well-suited for a multitude of applications. These devices exemplify Desa Tech’s commitment to innovation, quality, and sustainability, making them a preferred choice for engineers and manufacturers in various sectors striving for excellence in their designs.