Desa Tech CGCFTP, CGCFTN Troubleshooting, Observed Problem, Possible Cause, Remedy

Models: CGCFTP CGCFTN

1 30
Download 30 pages 60.84 Kb
Page 20
Image 20
TROUBLESHOOTING

20

TROUBLESHOOTING

TROUBLESHOOTING

Note: For additional help, visit DESA Heating Products’ technical service web site at www.desatech.com.

Note: All troubleshooting items are listed in order of operation.

OBSERVED PROBLEM WARNING: Turn off and un- plug fireplace and let cool before servicing. Only a qualified ser- vice person should service and repair fireplace.

POSSIBLE CAUSE CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

When ignitor button is pressed, there is no

1.

Ignitor cable pinched or wet

1.

Free ignitor cable if pinched by any

spark at ODS/pilot

 

 

 

metal or tubing. Keep ignitor cable dry

 

2.

Ignitor electrode not connected to igni-

2.

Reconnect ignitor cable

 

 

tor cable

 

 

 

3.

Broken ignitor cable

3.

Replace ignitor cable

 

4.

Bad piezo ignitor

4.

Replace piezo ignitor

 

5.

Ignitor electrode broken

5.

Replace pilot assembly

 

6.

Ignitor electrode positioned wrong

6.

Replace pilot assembly

 

 

 

 

 

When ignitor button is pressed, there is

1.

Gas supply turned off or equipment

1.

Turn on gas supply or open equipment

spark at ODS/pilot but no ignition

 

shutoff valve closed

 

shutoff valve

 

2.

Control knob not in PILOT position

2.

Turn control knob to PILOT position

 

3.

Control knob not pressed in while in

3.

Press in control knob while in PILOT

 

 

PILOT position

 

position

 

4.

Air in gas lines when installed

4.

Continue holding down control knob.

 

 

 

 

Repeat igniting operation until air is

 

 

 

 

removed

 

5.

Depleted gas supply (propane/LP only)

5.

Contact local propane/LP gas company

 

6.

ODS/pilot is clogged

6.

Clean ODS/pilot (see Cleaning and

 

 

 

 

Maintenance, page 19) or replace ODS/

 

 

 

 

pilot assembly

 

7.

Gas regulator setting is not correct

7.

Replace gas regulator

 

 

 

 

 

ODS/pilot lights but flame goes out when

1.

Control knob not fully pressed in

1.

Press in control knob fully

control knob is released

2.

Control knob not pressed in long enough

2.

After ODS/pilot lights, keep control

 

 

 

 

knob pressed in 30 seconds

 

3.

Safety interlock system has been triggered

3.

Wait one minute for safety interlock sys-

 

 

 

 

tem to reset. Repeat ignition operation

 

4.

Equipment shutoff valve not fully open

4.

Fully open equipment shutoff valve

 

5.

Thermocouple connection loose at con-

5.

Hand tighten until snug, then tighten 1/4

 

 

trol valve

 

turn more

 

6.

Pilot flame not touching thermocouple,

6.

A) Contact local propane/LP or natural

 

 

which allows thermocouple to cool,

 

gas company

 

 

causing pilot flame to go out. This prob-

 

 

 

 

lem could be caused by one or both of

 

B) Clean ODS/pilot (see Cleaning and

 

 

the following:

 

Maintenance, page 19) or replace ODS/

 

 

A) Low gas pressure

 

pilot assembly

 

 

B) Dirty or partially clogged ODS/pilot

 

 

 

7.

Thermocouple damaged

7.

Replace pilot assembly

 

8.

Control valve damaged

8.

Replace control valve

REMEDYManual backgroundManual backgroundManual backgroundManual backgroundForManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background.Manual backgroundManual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual background

111044-01D

Page 20
Image 20
Desa Tech CGCFTP, CGCFTN installation manual Troubleshooting, Observed Problem, Possible Cause, Remedy