RIDGID BS1400 manual Troubleshooting, Trouble Probable Cause Remedy

Models: BS1400

1 32
Download 32 pages 20.56 Kb
Page 25
Image 25

Troubleshooting

Motor

NOTE: Motors used on wood-working tools are particularly susceptible to the accumulation of sawdust and wood chips and should be blown out or “vacuumed” frequently to prevent interference with normal motor ventilation and proper operation of the centrifugally-operated starting switch.

Trouble

 

Probable Cause

 

Remedy

 

 

 

 

 

 

 

 

Excessive noise

1. Motor

1.

Have motor checked by qualified service tech-

 

 

 

 

nician. Repair service is available your nearest

 

 

 

 

Authorized Service Center store.

 

 

 

 

 

Motor fails to develop full

1.

Circuit overloaded with light,

1.

Do not use other appliances or motors on

power. Note Low Voltage:

 

appliances and other motors.

 

same circuit when using the saw.

Power output of motor

2.

Undersize wires or circuit too

2.

Increase wire sizes, or reduce length of wiring.

decreases rapidly with

 

long.

 

See “Motor specifications and Electrical

decrease in voltage at

3.

General overloading of power

 

Requirements” section.

motor terminals. For

 

company facilities.

3.

Request a voltage check from the power com-

example, a reduction of

 

 

 

pany.

10% in voltage causes a

 

 

 

 

reduction of 19% in maxi-

 

 

 

 

mum power output of

 

 

 

 

which the motor is capa-

 

 

 

 

ble, and a reduction of

 

 

 

 

20% in voltage causes a

 

 

 

 

reduction of 36% in maxi-

 

 

 

 

mum power output

 

 

 

 

 

 

 

 

 

Motor starts slowly or fails

1.

Low voltage.

1.

Request voltage check from the power com-

to come up to full speed.

 

 

 

pany. Check size of circuit wiring.

 

2.

Windings burned out or open.

2.

Have motor repair or replaced.

 

3.

Starting switch not operating.

3.

Blow out sawdust from motor. Have motor

 

 

 

 

repaired.

 

 

 

 

 

Motor overheats

1.

Motor overloaded.

1.

Feed work slower into blade.

 

2.

Improper cooling (air circula-

2.

Clean out sawdust to provide normal air circu-

 

 

tion restricted through motor

 

lation through motor. See “Maintenance” sec-

 

 

due to sawdust accumulation).

 

tion.

 

 

 

 

Starting switch in motor

1. Burned switch contacts (due to

1.

Have switch replaced and request a voltage

will not operate.

 

extended hold-in periods

 

check from the power company.

 

 

caused by low line voltage,

 

 

 

 

etc.)

 

 

 

2.

Shorted capacitor.

2.

Have capacitor tested and replace if defective.

 

3.

Loose or broken connections.

3.

Have wiring checked and repaired.

 

 

 

 

 

Motor stalls (resulting in

1.

Starting switch not operating.

1.

Have switch replaced.

blown fuses or tripped cir-

2. Voltage too low to permit motor

2.

Request voltage check from the power com-

cuit breakers).

 

to reach operating speed.

 

pany.

 

3.

Fuses or circuit breakers do

3.

Install proper size fuses or circuit breakers.

 

 

not have sufficient capacity.

 

 

 

 

 

 

 

Frequent opening of fuses

1.

Motor overloaded.

1.

Feed work slower into blade.

or circuit breakers.

2.

Fuses or circuit breakers do

2.

Install proper size fuses or circuit breakers.

 

 

not have sufficient capacity.

 

Check that wiring will handle load.

 

3.

Starting switch not operating

3.

Have switch replaced. Blow out sawdust.

 

 

(motor does not reach speed).

 

 

 

 

 

 

 

25