Troubleshooting Checklist

4.2TROUBLESHOOTING CHECKLIST

If the 2H253-25R is not working properly, refer to Table 4-2for a checklist of possible problems, causes, and recommended actions to resolve the problem.

Table 4-2 Troubleshooting Checklist

Problem

Possible Cause

Recommended Action

 

 

 

All LEDs are

Loss of power.

Check for proper connection of the

OFF.

 

power cable and its access to a live

 

 

outlet.

 

 

 

 

Installed improperly.

Ensure that the 2H253-25R was

 

 

installed properly according to the

 

 

installation instructions in Chapter 3.

 

 

 

No Local

Autobaud is enabled, but the

Press ENTER (RETURN) (may take

Management

baud rate has not yet been

up to four times).

Password screen.

detected.

 

 

 

 

 

Terminal setup is not correct.

Refer to the SmartSwitch Series

 

 

2E253, 2H252, 2H253, and 2H258

 

 

Local Management User’s Guide for

 

 

proper setup procedures.

 

 

 

 

Improper console cable pinouts.

Refer to Appendix A for proper

 

 

console port pinouts.

 

 

 

 

Corrupt firmware image, or

If possible, attempt to download the

 

hardware fault.

image to the 2H253-25R again. Refer

 

 

to Section B.3 for instructions to clear

 

 

NVRAM.

 

 

 

Cannot navigate

Improper Community Names

1. Refer to the SmartSwitch Series

beyond Password

Table.

2E253, 2H252, 2H253, and 2H258

screen.

 

Local Management User’s Guide for

 

 

the Community Names Table setup.

 

 

2. If you have forgotten the

 

 

Community Names, refer to

 

 

Appendix B for instructions on how

 

 

to set the mode switch to reset the

 

 

Community Names to their default

 

 

values.

 

 

 

Troubleshooting 4-5

Page 45
Image 45
Cabletron Systems 2H253-25R manual Troubleshooting Checklist, Off