B.3 SETTING THE MODE SWITCHES

Setting the Mode Switches

B.3 SETTING THE MODE SWITCHES

Figure B-2shows the location of the mode switches and the switch settings for normal operation. These switches are set at the factory and rarely need to be changed.

Switch definitions and positions are as follows:

Switches 1 through 4 – For Cabletron Systems use only.

Switch 5 – COM Port Autobaud. The default (OFF) position enables Autobaud sensing on the COM port for Local Management sessions. Changing the switch to the ON position disables Autobaud sensing and sets the COM port to 9600 baud for Local Management sessions.

TOP VIEW WITHOUT COVER

Primary

Power

Supply

Redundant

Power

Supply

MODE SWITCH BANK

ON

OFF

1 2 3 4 5 6 7 8

FRONT PANEL

25041-11

Figure B-2 Mode Switch Location

Switch 6 – Forced BootP.

NOTE

After changing the position of switch 6, DO NOT reapply power to the chassis until there is a station on the network acting as a BootP server, which contains the downloadable firmware image file.

Optional Installations and Mode Switch Bank Settings

B-5