Desa Tech CGFB32NC Installing Blower Accessory Model CGFB32C only, Conventional Installation

Models: CGFB32C CGFB32NC

1 16
Download 16 pages 52.28 Kb
Page 8
Image 8

UNVENTED (VENT-FREE) FIREBOX

INSTALLATION

Continued

INSTALLING BLOWER

ACCESSORY (MODEL

CGFB32C ONLY)

You may install blower accessory GA3750 with conventional installation (below) or with

built-in installation (page 10) with model CGFB32C only. To install blower accessory, see instruction sheet included with the kit.

Conventional Installation of

Blower Accessory

1.Install blower assembly per instruction sheet included in blower accessory kit.

2.Before replacing bottom of firebox, route blower power cord through hole in support bracket in bottom of firebox and through hole in side of firebox to grounded, three-prong 120 volt electri- cal outlet (see Figure 8). Plug electri- cal cord into outlet.

3.Replace bottom of firebox.

NOTICE: A certified electrician must connect electrical wiring to

duplex outlet for built-in installa- tion. Follow all local codes. In

absence of local codes, follow

the National Electrical Code, ANS/ NFPA 70 (Latest Edition).

Electrical

Outlet

Built-In Installation of Blower

Accessory

1.Install blower assembly per instruction sheet included.

2.Before replacing bottom of firebox, remove screw holding duplex outlet to the support bracket in the bottom of firebox, Remove duplex outlet.

3.Clamp electrical cable into firebox through smallest hole using strain re- lief provided.

4.Route wires from electrical box through hole in side of heater and hole in sup- port bracket (see Figure 9).

5.Connect wires from the electrical box to duplex outlet. Match wire colors to those indicated on duplex outlet. Be sure to connect ground wire.

6.Replace duplex outlet with screw.

7.Plug blower power cord into duplex outlet.

8.Replace bottom of firebox.

Cables From

Electrical

Source

Duplex

Outlet

Screw

SlowerPower

Cord

INSTALLING LOG HEATER IN

FIREBOX

_]k CAUTION: Do not pick up log

base assembly by burners, This could damage burners. Only handle base by grates.

_k CAUTION: Do not remove the

metal data plates attached to the heater base assembly. The data plates contain Important warranty

Information.

1.Remove four screws holding firebox bottom in place.

2.Lift and remove firebox bottom (see Figure 10).

3.If installing GA3750 Blower Accessory (Model CGFB32C only), see Install- ing Blower Accessory.

4.Route flexible gas line from manual shutoff valve into firebox through side.

NOTICE: Most building cedes do not permit concealed gas con- nections. A flexible gas line is recommended to allow accessi-

bility from the firebox. The flex- ible gas supply line connection to the manual shutoff valve should be accessible,

5.Attach gas log heater base to firebox bottom with four screws included with

base (see lnstallihg Heater Base As- sembly in log set owner's manual).

6.Replace firebox bottom and secure with

screws.

Side

Opening

Support Bracket

Opening

Slower Power

Cord

Figure 8 - Routing Blower Accessory Power Cord for Conventional Installation

Figure 9 - Routing Blower Accessory

Power Cord for Built-In Installation

B

Figure 10- Removing Firebox Bottom

8

1o3573

Page 8
Image 8
Desa Tech CGFB32NC Installing Blower Accessory Model CGFB32C only, Conventional Installation, SlowerPower Cord

CGFB32C, CGFB32NC specifications

Desa Tech has established a reputation for delivering innovative heating solutions, and their CGFB32NC and CGFB32C models are no exceptions. These gas-fired blue flame heaters are designed with user convenience, efficiency, and safety in mind, making them ideal options for both indoor and outdoor use.

One of the main features of the CGFB32NC and CGFB32C is their ability to produce consistent and reliable heat output. These models utilize a blue flame technology, which operates by pulling in air from the surrounding environment and heating it before circulating it throughout the space. This process not only enhances energy efficiency but also ensures that the heat distribution is even, providing a comfortable living or working atmosphere.

In terms of specifications, both models are equipped with variable heat settings, allowing users to customize the temperature according to their specific needs. The CGFB32NC and CGFB32C are also capable of heating spaces up to 1,000 square feet, making them suitable for garages, workshops, and large living areas. Their portability adds to their versatility, as they can easily be transported from one location to another.

Safety is paramount in any heating device, and Desa Tech has incorporated multiple safety features into these models. The CGFB32NC and CGFB32C come with an automatic shut-off valve that activates in case of an accidental tip-over or if the heater overheats, ensuring peace of mind for users. Additionally, both models are certified by the relevant safety standards, assuring consumers of their reliability and secure operation.

Another standout characteristic of these heaters is their straightforward operation. They feature an easy-to-use ignition system, allowing for quick startups without the need for complicated setups. Both models are also designed to run quietly, making them suitable for use in environments where noise levels need to be kept to a minimum.

Durability is a key consideration for any heating appliance, and Desa Tech has focused on quality materials and construction in the CGFB32NC and CGFB32C. These heaters are built to withstand the rigors of daily use, ensuring longevity and providing good value for investment.

Overall, the Desa Tech CGFB32NC and CGFB32C gas-fired blue flame heaters stand out for their efficiency, safety, and user-friendly features. Whether it's for home, garage, or workshop heating needs, these models deliver reliable performance and comfort, making them an excellent choice for countless applications.