TROUBLESHOOTING

OWNER’S MANUAL

TROUBLESHOOTING

Note: For additional help, visit DESA International’s Technical Service web site at www.desatech.com.

Note: All troubleshooting items are listed in order of operation.

OBSERVED PROBLEM WARNING: Turn off and un- plug heater and let cool before servicing. Only a qualified ser- vice person should service and repair heater.

POSSIBLE CAUSE CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

When ignitor button is pressed, there is no spark at ODS/pilot

1.Ignitor electrode not connected to igni- tor cable

2.Ignitor cable pinched or wet

3.Piezo ignitor nut is loose

4.Broken ignitor cable

5.Bad piezo ignitor

6.Ignitor electrode broken

7.Ignitor electrode positioned wrong

1.Reconnect ignitor cable

2.Free ignitor cable if pinched by any metal or tubing. Keep ignitor cable dry

3.Tighten nut holding piezo ignitor to base panel of log set. Nut is located behind base panel.

4.Replace ignitor cable

5.Replace piezo ignitor

6.Replace piezo ignitor

7.Replace piezo ignitor

When ignitor button is pressed, there is spark at ODS/pilot but no ignition

1.Gas supply turned off or manual shutoff valve closed

2.Control knob not in PILOT position

3.Control knob not pressed in while in PI- LOT position

4.Air in gas lines when installed

5.Depleted gas supply

6.ODS/pilot is clogged

7.Gas regulator setting is not correct

1.Turn on gas supply or open manual shutoff valve

2.Turn control knob to PILOT position

3.Press in control knob while in PILOT position

4.Continue holding down control knob. Re- peat igniting operation until air is removed

5.Contact local propane/LP gas company

6.Clean ODS/pilot (see Cleaning and Maintenance, page 18) or replace ODS/ pilot assembly

7.Replace gas regulator

ODS/pilot lights but flame goes out when

1.

Control knob not fully pressed in

control knob is released

2.

Control knob not pressed in long enough

 

3.

Safety interlock system has been trig-

 

 

gered (thermostat models only)

 

4.

Manual shutoff valve not fully open

 

5.

Pilot flame not touching thermocouple,

 

 

which allows thermocouple to cool,

 

 

causing pilot flame to go out. This prob-

 

 

lem could be caused by one or both of

 

 

the following:

 

 

A) Low gas pressure

 

 

B) Dirty or partially clogged ODS/pilot

 

6.

Thermocouple connection loose at con-

 

 

trol valve

 

7.

Thermocouple damaged

 

8.

Control valve damaged

1.Press in control knob fully

2.After ODS/pilot lights, keep control knob pressed in 30 seconds

3.Wait one minute for safety interlock sys- tem to reset. Repeat ignition operation

4.Fully open manual shut-off valve

5.A) Contact local propane/LP gas company

B) Clean ODS/pilot (see Cleaning and Maintenance, page 18) or replace ODS/ pilot assembly

6.Hand tighten until snug, then tighten 1/4 turn more

7.Replace thermocouple

8.Replace control valve

www.desatech.com

Continued