UNVENTED
OPTIONAL POSITIONING OF THERMOSTAT SENSING BULB
FOR MASONRY AND FACTORY-BUILT METAL FIREPLACE
If your log set cycles to pilot, but the room temperature drops to a lower than ideal comfort level before the log set comes back on, you may want to reposition the thermostat sensing bulb.
The thermostat sensing bulb is located on the gas valve assembly. This location al- lows the thermostat to keep the room tem- perature at an ideal comfort level for most fireplace applications. For positioning the thermostat sensing bulb elsewhere, an adhe-
Tools needed:
•5/16" hex driver or socket
1. | Locate the gas valve assembly and ther- |
| mostat sensing bulb (see Figure 31). |
2. | With 5/16" hex driver or socket, loosen |
| the thermostat screw. Carefully slide |
| the thermostat sensing bulb out of the |
| retaining clamp (see Figure 33). |
| Note: Do not remove the screw. Make |
| sure you tighten the screw after remov- |
| ing the thermostat sensing bulb. |
| IMPORTANT: Do not force or bend the |
| thermostat sensing bulb or capillary. A |
| crimped capillary will not allow ther- |
| mostat to operate properly. It cannot be |
| repaired, the valve must be replaced. |
4.The mounting clip must be a minimum of 3" from bottom of fireplace to pre- vent crimping of capillary. Once you have decided on a location, clean the area thoroughly. Remove the paper backing from the adhesive on back of mounting clip. Press the clip into the new location so that the thermostat sensing bulb will be positioned vertically with the capillary at the bot- tom (see Figure 37). Slide the thermo- stat sensing bulb into the clip.
IMPORTANT: Do not crimp capillary.
Gas Valve
Assembly
Thermostat
Sensing Bulb
Figure 31 - Location of Gas Valve Assembly and Thermostat Sensing Bulb
Figure 32 -
Capillary
Thermostat
Sensing Bulb
Mounting Clip
Figure 34 - Locating Thermostat Sensing Bulb on Masonry Fireplace
Thermostat
Sensing
Bulb
Adhesive- backed Mounting Clip
Figure 35 - Locating Thermostat Sensing Bulb on
Thermostat
Sensing
Bulb
Adhesive- |
|
backed |
|
Mounting |
|
Clip | Glass Doors |
|
Figure 36 - Installing Thermostat Sensing Bulb behind Glass Doors
3. The thermostat sensing bulb may be |
located to the lower right front side of |
fireplace. Determine location of sens- |
ing bulb, but do not mount sensing bulb |
until step 5. If you have a masonry fire- |
place, see Figure 34 for location. |
If you have a |
Thermostat
Screw Sensing
Capillary
Thermostat
Sensing
Bulb
Adhesive- backed Mounting Clip
place, see Figure 35 for location. |
If your fireplace has glass doors, posi- |
tion sensing bulb directly behind door |
gap on right bottom side (see Figure 36). |
Retaining Bulb
Clamp
Figure 33 - Removing Thermostat Sensing Bulb
Do Not Crimp
Capillary
Figure 37 - Positioning the Thermostat Sensing Bulb in the Vertical Position with the Capillary at the Bottom
22 | 103425 |