Desa Tech CGN20TL Trouble- Shooting, Continued, Observed, Possible, Problem, Cause, Remedy

Models: CGN20T CGN30TL CGN30T CGN20TL

1 32
Download 32 pages 39.83 Kb
Page 24
Image 24
TROUBLE- SHOOTING

24

TROUBLE- SHOOTING

Continued

OBSERVED

POSSIBLE

 

 

 

PROBLEM

CAUSE

REMEDY

 

 

 

 

 

 

Burner does not light

1.

Burner orifice is

1.

Clean burner (see Clean-

after ODS/pilot is lit

 

clogged

 

ing and Maintenance,

 

 

 

 

page 22) or replace burner

 

 

 

 

orifice

 

2.

Burner orifice diameter

2.

Replace burner orifice

 

 

is too small

 

 

 

 

3.

Inlet gas pressure is

3.

Contact local natural gas

 

 

too low

 

company

 

 

 

 

 

 

Delayed ignition of

1.

Manifold pressure is

1.

Contact local natural gas

burner

 

too low

 

company

 

2.

Burner orifice is

2.

Clean burner (see Clean-

 

 

clogged

 

ing and Maintenance,

 

 

 

 

page 22) or replace burner

 

 

 

 

orifice

 

 

 

 

 

 

Burner backfiring

1.

Burner orifice is

1.

Clean burner (see Clean-

during combustion

 

clogged or damaged

 

ing and Maintenance,

 

 

 

 

page 22) or replace burner

 

 

 

 

orifice

 

2.

Burner damaged

2.

Replace burner

 

3.

Gas regulator defective

3.

Replace gas regulator

 

 

 

 

 

Yellow flame during

1. Not enough air

1.

Check burner for dirt and

burner combustion

 

 

 

debris. If found, clean

 

 

 

 

burner (see Cleaning and

 

 

 

 

Maintenance, page 22)

 

2.

Gas regulator defective

2.

Replace gas regulator

 

 

 

 

 

Slight smoke or odor

1. Residues from manu-

1.

Problem will stop after a

during initial opera-

 

facturing processes

 

few hours of operation

tion

 

 

 

 

 

 

 

 

 

 

Heater produces a

1. Turning control knob

1.

Turn control knob to LO

whistling noise when

 

to HI position when

 

position and let warm up

burner is lit

 

burner is cold

 

for a minute

 

2.

Air in gas line

2.

Operate burner until air is

 

 

 

 

removed from line. Have

 

 

 

 

gas line checked by local

 

 

 

 

natural gas company

 

3.

Air passageways on

3.

Observe minimum installa-

 

 

heater blocked

 

tion clearances (see Figure

 

 

 

 

4, page 10)

 

4.

Dirty or partially

4.

Clean burner (see Clean-

 

 

clogged burner orifice

 

ing and Maintenance,

 

 

 

 

page 22) or replace burner

 

 

 

 

orifice

103873

Page 24
Image 24
Desa Tech CGN20TL, CGN30T Trouble- Shooting, Continued, Observed, Possible, Problem, Cause, Remedy, ing and Maintenance