TROUBLE- |
| WARNING ICONG 001 WARNING |
SHOOTING |
| If you smell gas |
Continued |
| • Shut off gas supply. |
| • Do not try to light any appliance. | |
|
| |
|
| • Do not touch any electrical switch; do not use any phone in your |
|
| building. |
|
| • Immediately call your gas supplier from a neighbor’s phone. Follow |
|
| the gas supplier’s instructions. |
|
| • If you cannot reach your gas supplier, call the fire department. |
|
|
|
IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.
OBSERVED | POSSIBLE | REMEDY | |||
PROBLEM | CAUSE | ||||
|
|
|
|
|
|
Heater produces a | 1. | Metal expanding while | 1. | This is common with | |
clicking/ticking noise |
| heating or contracting |
| most heaters. If noise is | |
just after burner is lit |
| while cooling |
| excessive, contact quali- | |
or shut off |
|
|
| fied service person | |
|
|
|
|
|
|
Heater produces | 1. | Heater burning vapors | 1. | Ventilate room. Stop | |
unwanted odors |
| from paint, hair spray, |
| using odor causing | |
|
| glues, etc. See IMPOR- |
| products while heater is | |
|
| TANT statement |
| running | |
|
| above). |
|
|
|
| 2. | Gas leak. See Warn- | 2. | Locate and correct all | |
|
| ing statement at top |
| leaks (see Checking Gas | |
|
| of page |
| Csonnections, page 15) | |
|
|
|
|
|
|
Heater shuts off in | 1. | Not enough fresh air is | 1. | Open window and/or door | |
use (ODS operates) |
| available |
| for ventilation | |
| 2. | Low line pressure | 2. | Contact local propane/LP | |
|
|
|
| gas company | |
| 3. | ODS/pilot is partially | 3. | Clean ODS/pilot (see | |
|
| clogged |
| Cleaning and Mainte- | |
|
|
|
| nance, page 22) | |
|
|
|
|
|
|
Gas odor even when | 1. | Gas leak. See Warn- | 1. | Locate and correct all | |
control knob is in |
| ing statement at top |
| leaks (see Checking Gas | |
OFF position |
| of page |
| Connections, page 15) | |
| 2. | Control valve defective | 2. | Replace control valve | |
|
|
|
|
|
|
Gas odor during | 1. | Foreign matter be- | 1. | Take apart gas tubing and | |
combustion |
| tween control valve |
| remove foreign matter | |
|
| and burner |
|
|
|
| 2. | Gas leak. See Warn- | 2. | Locate and correct all | |
|
| ing statement at top |
| leaks (see Checking Gas | |
|
| of page |
| Connections, page 15) | |
|
|
|
|
| |
Moisture/condensa- | 1. | Not enough combus- | 1. | Refer to Air for Combus- | |
tion noticed on |
| tion/ventilation air. |
| tion and Ventilation | |
windows |
|
|
| requirements (page 5) |
25
103873